background image

VII 

 

WARNING

 

Warnings for AC Power Supply: 

 

 

 

If the attached AC power cable does not fit the 

receptacle, do not alter the AC power cable and do not 
plug it forcibly. Failure to comply may cause electric 
shock and/or fire. 

   

 

Use an AC power cable which complies with the safety 

 

standard of the country. 

   

 

Do not touch the plug of the AC power cable when your 

 

hands are wet. This may cause electric shock. 

     

 

This product is connected signal ground with frame  

    ground. If your developing product is transformless (not 
    having isolation transformer of AC power), this may cause 
    electric shock. Also, this may give an unrepairable  
    damage to this product and your developing one. 

      While developing, connect AC power of the product to  

    commercial power through isolation transformer in order 
    to avoid these dangers. 

     

 

If other equipment is connected to the same branch  

    circuit care should be taken not to overload the circuit.  
    Refer to nameplate for electrical ratings. 

 

 When installing this equipment, insure that a reliable 

ground connection is maintained. 

 

Содержание FP-144L

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...SH7211 Group FP 144L User System Interface Board User s Manual User s Manual Rev 1 01 2006 08 Renesas Microcomputer Development Environment System SuperH Family SH7210 Series R0E572110CFK00...

Страница 4: ......

Страница 5: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Страница 6: ......

Страница 7: ...board is used to connect the evaluation chip unit to the user system This user system interface board must only be used for the above purpose Limited Applications This emulator product is not authoriz...

Страница 8: ...on or some experiment else 2 In no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this emulator 3 Renesas Solutions Corporation strives to renovate or...

Страница 9: ...hases the emulator product from you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR...

Страница 10: ...system All Rights Reserved 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Renesas semiconductor products Renesas assumes no respons...

Страница 11: ...alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazar...

Страница 12: ...VI means WARNING or CAUTION Example CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION Example DISASSEMBLY PROHIBITED means A FORCIBLE ACTION Example UNPLUG THE POWER CABLE FROM THE RECEPTACLE...

Страница 13: ...nnected signal ground with frame ground If your developing product is transformless not having isolation transformer of AC power this may cause electric shock Also this may give an unrepairable damage...

Страница 14: ...ipment Warnings to Be Taken for This Product Do not disassemble or modify this product Personal injury due to electric shock may occur if this product is disassembled and modified Make sure nothing fa...

Страница 15: ...connecting the AC power cable Check if the power is supplied by the LED of AC adapter Cautions to Be Taken for This Product Use caution when handling this product Be careful not to apply a mechanical...

Страница 16: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E200F emulator...

Страница 17: ...i Preface The R0E572110CFK00 is a user system interface board that connects a user system for the SH7211 FP 144L package to the SH7211 E200F emulator R0E0200F1EMU00 or R0E572110VKK00...

Страница 18: ...5 3 1 3 Fastening Cable Head 5 3 2 Connecting User System Interface Board to EV Chip Unit 7 3 3 Recommended Dimensions for User System Mount Pad Footprint 9 3 4 Dimensions for External Bus Trace Unit...

Страница 19: ...tem interface board for the FP 144L package Please make sure you have all of these components when unpacking Board Screws M2 0 x 10 mm Spacer IC socket User system EV chip unit Screws M2 0 x 6 mm Sock...

Страница 20: ...ty Remarks 1 Board 1 With four spacers 2 6MP x 11 mm 2 IC socket 1 For the FP 144L package to be mounted on the user system 3 Socket cover 1 For the FP 144L package for installing MPU 4 Screws M2 0 x...

Страница 21: ...ntal Conditions Item Specifications Temperature Operating 10 to 35 C Storage 10 to 35 C Humidity Operating 35 to 80 RH no condensation Storage 35 to 80 RH no condensation Vibration Operating 2 45 m s...

Страница 22: ...ctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable...

Страница 23: ...ignificantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 I...

Страница 24: ...6 Board Screws M2 0 x 10 mm User system IC socket NQPACK144SD manufactured by Tokyo Eletech Corporation Pin 1 Figure 2 Connecting User System Interface Board to User System...

Страница 25: ...er system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user...

Страница 26: ...EV chip unit Connector No User I F Connector 1 CN3 EV Chip Unit Connector No Board Connector No UCN1 UCN2 User I F Connector 2 CN4 External bus trace unit Pin 1 Figure 3 Connecting User System Interf...

Страница 27: ...ows the recommended dimensions for the mount pad footprint for the user system with an IC socket for an FP 144L package NQPACK144SD manufactured by Tokyo Eletech Corporation Note that the dimensions i...

Страница 28: ...0 35 17 5 19 00 max 23 00 min 0 5 0 50 Location determination hole Unit mm Dimension and tolerance Tolerance 0 05 0 10 0 15 0 20 0 30 Dimension Up to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 or abov...

Страница 29: ...ace board are shown in figure 5 125 0 90 0 External bus trace unit Board Spacer 125 0 90 0 110 0 20 0 EV chip unit 90 0 45 0 5 0 30 0 60 0 5 0 Pin 1 Unit mm Dimension and tolerance Tolerance 0 05 0 10...

Страница 30: ...144SD manufactured by Tokyo Eletech Corporation User system Spacer 6 0 EV chip unit Pin 1 Top view External bus trace unit Optional memory unit 39 19 24 5 24 5 39 19 Unit mm Dimension and tolerance To...

Страница 31: ...9 19 24 5 24 5 39 19 EV chip unit External bus trace unit Pin 1 Unit mm Dimension and tolerance Tolerance 0 05 0 10 0 15 0 20 0 30 Dimension Up to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 or above F...

Страница 32: ...kyo Eletech Corporation User system 39 19 24 5 24 5 39 19 Pin 1 Unit mm Dimension and tolerance Tolerance 0 05 0 10 0 15 0 20 0 30 Dimension Up to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 or above F...

Страница 33: ...h the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MPU does not operate correctly cracks might have occurred in the solder Check conduct...

Страница 34: ...16 MPU SH7211 Screws M2 0 x 6 mm Socket cover Pin 1 User system IC socket NQPACK144SD manufactured by Tokyo Eletech Corporation Figure 9 Installing MPU to User System...

Страница 35: ...ources as the MPU clock For details refer to the SH7211 E200F Emulator User s Manual R0E0200F1EMU00E To use the emulator internal clock Select the clock in the emulator by the CLOCK command emulator c...

Страница 36: ...imensions of the recommended mount pad for the IC socket for this user system interface board are different from those of the MPU 4 This user system interface board is specifically designed for the SH...

Страница 37: ...blication Date Rev 1 01 August 8 2006 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global Strategic Communication Div Renesas Solutions Corp...

Страница 38: ...Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Technology Taiwan Co L...

Страница 39: ......

Страница 40: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan SH7211 Group FP 144L User System Interface Board REJ10J1317 0101 User s Manual...

Отзывы: