5. Connection Procedure (See Figure 3) 

 

The procedure for connecting the M3T-FLX-144NSE is shown 
below. 

 

(1)  Mount the NQPACK144SE on the target board. 

(2)  Attach the YQPACK144SE on the NQPACK144SE. 

(3) Secure the four corners of the YQPACK144SE with the 

YQ-GUIDE's. 

 

Do not use the screws included with the 

YQPACK144SE for fixing the YQPACK144SE. 

 

The screwdriver included with the NQPACK144SE is 

used for fixing the HQPACK144SE. Do not use if for 

fixing the YQ-GUIDE's. 

(4) Connect the probe of the emulation pod to the 

M3T-FLX-144NSE. 

(5)  Attach the M3T-FLX-144NSE on the YQPACK144SE. 
 

Figure 3 Connection procedure of the M3T-FLX-144NSE 
 
 

6. External Dimensions and a Sample Foot Pattern 

 

 

Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-144NSE 
 

Probe of emulation pod

M3T-FLX-144NSE

YQ-GUIDE (x4)

YQPACK144SE

NQPACK144SE

144-pin 0.4-mm-pitch
(144PFB-A) foot pattern

(1)

(2)

(3)

(5)

(4)

Be sure to use a 
slotted screwdriver.

   : No. 1 pin
Be sure to align the pins.

55.0

21.8

40

.0

0.225

0.4

15.1

19.1

15

.1

19

.1

Unit: mm