Renesas Converter Board M3T-F160-100NRB Скачать руководство пользователя страница 5

 

(3/4)

 

5. Connection Procedure 

(See Figure 3)

 

 

The procedure for connecting the M3T-F160-100NRB is 
shown below. 

 

(1)  Mount the NQPACK100RB on the user system. 

(2)  Attach the YQPACK100RB on the NQPACK100RB. 

(3) Secure the four corners of the YQPACK100RB with the 

YQ-GUIDE's. 

 

Do not use the screws included with the 

YQPACK100RB for fixing the YQPACK100RB. 

 

Do NOT use the screwdriver included with the 

NQPACK100RB for fixing the YQ-GUIDE's. That is 

used only for the HQPACK100RB168 or 

HQPACK100RB1622. 

(4) Attach the probe of the emulation pod to the M3T-

F160-100NRB. 

(5)  Connect M3T-F160-100NRB to the emulator probe. 

 

 

YQ-GUIDE -1

YQPACK100RB

NQPACK100RB

100-pin 0.65-mm-pitch
(PRQP0100JB-A, 
formerly 100P6S-A) foot pattern

(5)

(4)

(1)

(2)

(3)

Use a slotted screwdriver.

: No.1 pin

Be sure to align the pins.

M3T-F160-100NRB

FLX160-PRB, 

M3xxxxTx-EPB

or

M3xxxxTx-CPE

Figure 3 Connection procedure of the M3T-F160-100NRB 
 

6. External Dimensions and a Sample Foot Pattern 

 

 

21.8

40

.0

5.

3

16

.5

0.35

0.65

13.8

17.2

19

.8

23

.2

Unit: mm

55.0

1

M3T-F160-100NRB REV.A

MADE IN JAPAN

IC1

CN1

CN2

30

31

50

51

80

81

100

1a

1b

40a

40b

1a

1b

40a

40b

Figure 4 External dimensions and a sample foot pattern of the M3T-F160-100NRB 
 

Отзывы: