background image

 

(3/4)

 

5. Connection Procedure (See Figure 3) 

 

The procedure for connecting the M30290T-80FPD is shown 
below. 

 

(1)  Mount the NQPACK080SD-ND on the user system. 

(2)  Attach the YQPACK080SD on the NQPACK080SD-ND. 

(3) Secure the four corners of the YQPACK080SD with the 

YQ-GUIDE's. 

 

Do not use the screws included with the 

YQPACK080SD for fixing the YQPACK080SD. 

 

The screwdriver included with the 

NQPACK080SD-ND is used for fixing the 

HQPACK080SD. Do not use it for fixing the 

YQ-GUIDE's. 

(4) Attach the M30290T-EPB or M30290T2-CPE and the 

M30290T-PTCB. 

(5)  Attach the M30290T-80FPD to the NQPACK080SD-ND. 

 

Figure 3 Connection procedure of the M30290T-80FPD 
 
 
 
 

6. External Dimensions and a Sample Foot Pattern

 

(See Figure 4) 

 

 

Figure 4 External dimensions and a sample foot pattern of the M30290T-80FPD 
 

80-pin 0.5-mm-pitch
(80P6Q-A) foot pattern

YQ-GUIDE (x4) *

YQPACK080SD *

NQPACK080SD-ND *

(1)

(2)

(4)

(5)

M30290T-PTCB

M30290T-80FPD

(3)

Be sure to use a
Phillips screwdriver.

M30290T-EPB

or

M30290T2-CPE

41.0

32

.0

16

.5

0.25

0.5

11.1

15.1

11

.1

15

.1

Unit: mm