Renco PREG-ALERT PRO Скачать руководство пользователя страница 6

PREG

ALERT

 

PRO

®

 

INSTRUCTION

 

MANUAL

  

Rev.

 

2

     

7/1/2007

 

DISPLAYS

 

(Note:

  

The

 

fine

 

ruler

 

divisions

 

are

 

not

 

shown

 

in

 

the

 

displays

 

below.

 

The

 

SENS

 

setting

 

is

 

for

 

illustration

 

only.)

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Above

 

are

 

several

 

screen

 

shots

 

illustrating

 

the

 

typical

 

displays

 

for

 

various

 

functions.

  

In

 

the

 

Pregnancy

:

  

OTHER

 

screen,

 

the

 

dotted

 

vertical

 

line

 

is

 

the

 

vertical

 

marker,

 

which

 

the

 

user

 

can

 

set

 

to

 

indicate

 

the

 

distance

 

of

 

any

 

spike

 

from

 

the

 

skin

 

surface.

  

The

 

heavy

 

solid

 

vertical

 

line

 

is

 

representative

 

of

 

the

 

actual

 

reading.

  

This

 

might

 

in

 

fact

 

be

 

multiple

 

closely

 

spaced

 

spikes.

  

In

 

the

 

COW

 

pregnancy

 

screen,

 

the

 

vertical

 

marker

 

is

 

shown

 

(for

 

illustration

 

purposes)

 

near

 

the

 

spike

 

reading

 

at

 

the

 

left

 

end

 

of

 

the

 

heavy

 

solid

 

bar

 

beneath

 

the

 

graticule.

  

If

 

the

 

test

 

is

 

attempting

 

to

 

identify

 

very

 

early

 

pregnancy,

 

then

 

since

 

the

 

reading

 

is

 

at

 

the

 

left

 

end

 

of

 

the

 

black

 

bar,

 

it

 

would

 

probably

 

be

 

indicating

 

a

 

thickened

 

uterine

 

wall.

  

(The

 

Deep

 

probe

 

would

 

be

 

used

 

for

 

this.)

  

In

 

actual

 

use,

 

if

 

the

 

user

 

wanted

 

to

 

know

 

the

 

actual

 

distance

 

being

 

measured,

 

the

 

spike

 

would

 

be

 

held

 

using

 

a

 

HOLD

 

key

 

(the

 

legend

 

“HOLD”

 

is

 

displayed)

 

and

 

DEPTH

 

keys

 

would

 

then

 

be

 

used

 

to

 

superimpose

 

the

 

vertical

 

marker

 

over

 

the

 

reading

 

and

 

the

 

distance

 

from

 

skin

 

to

 

spike

 

would

 

be

 

displayed.

   

 

The

 

LOIN

 

(high

 

range)

 

screen

 

shown

 

above

 

indicates

 

a

 

reading

 

at

 

150mm.

  

The

 

vertical

 

marker

 

prevents

 

anything

 

beyond

 

about

 

165mm

 

from

 

being

 

displayed.

  

Use

 

of

 

the

 

marker

 

is

 

optional.

  

Pressing

 

and

 

holding

 

the

 

OPTION

 

key

 

momentarily

 

while

 

in

 

the

 

LOIN

 

(high

 

range)

 

©2007

 

Renco

 

Corporation

  

 

Page

 

6

 

of

 

13

 

SENS-2

PREG

H O L D

B A T

O T H E R

100

M
M

PREGNANCY:

 

SCREEN

 

FOR

 

OTHER

 

SMALL

MEDIUM

 

MAMMALS

한국대리점: 길우트레이딩 02)2636-0009 팩스02)2636-4753   서울시 영등포구 양평동 3가 40-2 에이스테크노타워703호    [email protected]    www.gilwoo.co.kr

Содержание PREG-ALERT PRO

Страница 1: ...PREG ALERT PRO INSTRUCTIONS Rev 2 02 2636 0009 02 2636 4753 3 40 2 703 giltron chol com www gilwoo co kr...

Страница 2: ...d marker on each screen Adjust to depth of interest using right and left arrow keys This marker is calibrated and the distance is displayed on the right side of the screen In these Instructions scales...

Страница 3: ...that were generated by the ultrasonic pulses emitted by the transducer also called the probe Sound travels at different speeds through fat and muscle The instrument uses the appropriate speed for eac...

Страница 4: ...ment Select the FAT screen Most backfat testing in swine for example is done over the last rib and 40 60mm off the center line called the P2 test site This test site is also important for making the s...

Страница 5: ...use the important thing to look for is a strong high spike or group of spikes in the area of interest as displayed on the screen Pregnancy can be determined either by sensing the fetus or the interfa...

Страница 6: ...g to identify very early pregnancy then since the reading is at the left end of the black bar it would probably be indicating a thickened uterine wall The Deep probe would be used for this In actual u...

Страница 7: ...nd mares testing should be started on the left side If no pregnancy is detected then try the other side in all cases but be cautious of the results in ruminate animals where the rumen might interfere...

Страница 8: ...ting swine on right side and if not pregnant try again on the left side Testing can begin at 18 days testing every day until positive readings are obtained 2 days in a row Accuracy is greatest at 30 d...

Страница 9: ...35 days Test on left side if not successful It may be necessary to remove wool and dirt from test site Pregnancy Test Site for Alpacas Begin testing alpacas on the LEFT side at about 45 days Test on...

Страница 10: ...iangular region forward of the hook bone just behind the ribs and about 8 inches 20cm down from the backbone Locate the lowest spot in the fossa into which the probe will fit comfortably by pressing i...

Страница 11: ...MANUAL Rev 2 7 1 2007 Pregnancy Test Site Mares Side View Pregnancy Test Site for Mares Left Side View Right Back View 2007 Renco Corporation Page 11 of 13 02 2636 0009 02 2636 4753 3 40 2 703 giltron...

Страница 12: ...ation progresses you should move the probe downwards within the area shown by the outline in the side view Side View Position 2 is for use after approximately 90 100 days and the Standard probe may be...

Страница 13: ...x 612 333 9026 Email TechSupport Rencocorp com Internet http www rencocorp com CAUTION DO NOT USE THE PREG ALERT PRO ON HUMAN BEINGS CERTIFICATION AND COMPLIANCE FCC Required 15 21 Information to User...

Отзывы: