FAULTS AND FAULT SOLUTIONS
FAULT POSITION
FAULT REASON
SOLUTION
The valve is on
posi on but the
burner is not
burning!
Valve can not be
pushed
Change the valve
There is no gas
Turn on the valve
For the first me take out the air in the spiral pipe.
Hold pushed the valve for 3 minutes. Take out the air
in the pipe.
The injector of the burner is blocked. Change it.
Check the gas type.
Flame is
ex nguished in a
short me
Flame control probe is far from the flame. Make it
closer. If it is cracked change it.
Valve is on burning
posi on but burner
is not burning!
There is no gas
The burner nozzle is blocked, change it.
Burner air
adjustment is
wrong
Check
the air se ngs.
Burner nozzle is
wrong
Check the nozzle diameter.
Valve is on burning
posi on, burner is
burning but when
the valve is
released the
burner is
ex nguished!
Flame control
probe is not ge ng
magne c.
Fasten the probe screw
Probe is cracked change it
Valve is on
minimum posi on
but the flame is not
going on!
Flame is not going
on
Change the burner.
Bypass injector of
the valve is not
adjusted
Check the bypass injector