Note: 

When plug the ZRP-120 into the AC receptacles, there will be an air gap between ZRP-120 

and wall plate. User can use additional 1 or 2 washers to fill up this air gap and to stabilize the 

installation. 

 

ZRP-120 will not block lower outlet when plugged into upper outlet of a duplex wall receptacle 

and vice versa. Possible configurations are illustrated below.

 

 

Un-grounded AC outlet 

with center screw

 

Grounded AC outlet 

with center screw

 

Grounded AC outlet with 

upper and lower screw

 

Installed  at  upper 

AC outlet 

 

 

 

Installed  at  lower 

AC outlet

 

 

 

 

 

 

 

 

 

Grounded AC outlet 

with center screw 

Un-grounded AC outlet 

with center screw 

Grounded AC outlet with 

upper and lower screw

 

Содержание ZRP-120NA

Страница 1: ...performance to replicate Z Wave signals in a network The repeater re transmits an input Radio Frequency RF signal by routing the signal around obstacles and radio dead spots to ensure that the signal...

Страница 2: ...controllers operating on the same system A Z Wave network has its own unique ID code so that controllers not in the network cannot control the system Primary Controller The first controller is used to...

Страница 3: ...To avoid fire shock or death turn off power at circuit breaker or fuse and test that power is off before dismount or mount the unit with the screw In case that the user needs to mount the unit with sc...

Страница 4: ...lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa Possible configurations are illustrated below Un grounded AC outlet with center screw Grounded AC outlet with ce...

Страница 5: ...support Basic Command Class 4 All configuration parameters value will keep no change after exclude the unit from network 5 ZRP 120 can be included and operated in any Z Wave network with other Z Wave...

Страница 6: ...ntly deleted Please use this procedure only when the network primary controller is missing or otherwise inoperable Support for Association Groups ZRP 120 supports 1 association group Association Group...

Страница 7: ...e or abrasive cleansers on your unit 3 Keep the unit dust free by wiping it with a soft dry cloth 4 Do not disassemble your unit it contains no user serviceable parts Technical Specifications Model no...

Страница 8: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the s...

Страница 9: ...devices for indirect incidental special consequential or punitive damages including inter alia loss of profits savings data loss of benefits claims by third parties and any property damage or persona...

Отзывы: