REMKO WKF 120 compact Скачать руководство пользователя страница 10

10.

Release the casing of the indoor unit

Fig. 12: Release the cover

11.

Cut out the EPP housing sufficiently in

accordance with the marking on the back-left

corner using a knife.

Fig. 13: Cut out the EPP housing

12.

Take the indoor unit and install it on the very

back of the storage tank until it is optimally

integrated completely into the bottom part of

the EPP.

Now connect the two rear corrugated pipes

to the two free connections. Closed using a

cap in the factory!

IL-HP connection to changeover valve

(Fig. 15)

RF-HP connection behind the changeover

valve

 NOTICE!

Use the seals included in the box of

accessories!

A

B

Fig. 14: Install the indoor unit on the storage tank

Fig. 15: Connecting inlet to changeover valve

Fig. 16: Connecting inlet to changeover valve

 

 

 

REMKO WKF-compact

 

 

10

Содержание WKF 120 compact

Страница 1: ...Assembly instructions Read the instructions prior to performing any task REMKO WKF compact Inverter heat pump Installation instructions for the technician 0050 2016 06 Edition 1 en_GB ...

Страница 2: ...ad these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Страница 3: ...otes 4 1 5 Safety conscious working 4 1 6 Safety notes for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Environmental protection and recycling 6 1 12 Transport and packaging 6 2 Installing the heat pump 7 3 Unit dimensions for indoor unit 13 4 Spare parts 15 5 Index 16 3 ...

Страница 4: ...be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal ...

Страница 5: ...ls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation n The units and components should not be oper ated in areas where there is a heightened risk of damage Observe the minimum clearances n The units and components must be kept at an adequate distance from flammable explosive combustible ab...

Страница 6: ... not dis posed in household waste but only in accordance with local regulations and in an environmentally safe manner e g using certified firms and recy cling specialists or at collection points 1 12 Transport and packaging The devices are supplied in a sturdy shipping con tainer or inside the heat pump casing Please check the equipment immediately upon delivery and note any damage or missing part...

Страница 7: ...door unit properly in the installation space refer to and carry out the following steps 1 Place the indoor unit and the storage tank as close to each other as possible in the instal lation space Fig 1 Fig 1 Heat pump in delivery state 2 Cut the straps and remove the box and pro tective film Check the indoor units for damage Fig 2 Fig 2 Remove the boxes and the film and check for damage 7 ...

Страница 8: ... and right side If necessary loosen the screws by 1 2 turns Fig 4 Fig 4 Remove the sheet metal casing 5 Remove the rear casing frame from the storage tank In the installation space level the storage tank using the adjustment feet Fig 5 Fig 5 Remove the casing frame 6 Screw the numbered corrugated pipes that are included in the delivery into the connec tions that are numbered accordingly on the sto...

Страница 9: ...he box of accessories EDP 260008 If the storage tank is still to be operated via a solar plant the lower storage tank probe must also be installed Fig 8 Installation of the immersion probe 8 Unpack the top part of the WKF and place it on a suitable surface Fig 9 Unpacking WKF compact top part 1 Fig 10 Unpacking WKF compact top part 2 9 Remove the front cover Fig 11 Remove front cover 9 ...

Страница 10: ...til it is optimally integrated completely into the bottom part of the EPP Now connect the two rear corrugated pipes to the two free connections Closed using a cap in the factory IL HP connection to changeover valve Fig 15 RF HP connection behind the changeover valve NOTICE Use the seals included in the box of accessories A B Fig 14 Install the indoor unit on the storage tank Fig 15 Connecting inle...

Страница 11: ...f the storage tank on the front left Fig 20 A and install them upwards through the openings provided for them in the casing cover Fig 20 B Circulation 4 HW outlet 3 CW inlet 5 Use seals If the connection is not used for a circulation it must be properly sealed to the storage tank directly A B 2 1 4 3 Fig 20 Domestic water connection 1 Hot water outlet 2 Circulation 3 Drain valve 4 Cold water inlet...

Страница 12: ...s the front sheet Fix the operating unit by also inserting the frame into the opening as far as the Con troller Fig 24 Indoor unit with operating unit 19 After successfully installing the Indoor unit of the WKF compact heat pump the entire system must be stamped in accordance with the DIN standard During installation ensure that the dirt trap that is included in the delivery is installed in the re...

Страница 13: ...or indoor units WKF compact Pipe connection arrangement A B 8 2 1 0 1 2 8 8 2 8 2 3 0 3 1 5 3 2 7 8 135 205 142 212 368 384 465 508 50 578 50 267 135 142 212 205 267 368 134 50 164 50 134 50 164 50 384 465 508 50 578 50 7 8 8 2 1 0 1 2 8 8 2 8 2 3 6 5 5 0 2 6 5 3 2 0 3 1 Fig 26 Pipe connection arrangement A WKF B WKF compact 13 ...

Страница 14: ...ections A WKF B WKF compact 1 Hot water 2 Circulation 3 Cold water supply 4 Heating inlet 5 Heating return flow 6 Refrigerant liquid pipe 3 8 7 Refrigerant heat gas pipe 5 8 8 2 Heat generator return flow heat pump outlet 9 Safety assembly 10 2 Heat generator inlet heat pump inlet 11 Solar connections REMKO WKF compact 14 ...

Страница 15: ...top 1250mm 259050 3 Corrugated tube 4 circ connection on middle 1600mm 259050 4 Corrugated tube 5 KW connection on bottom 2400mm 259050 5 1 x flat gasket for the 3 way valve outside 39mm x inside 27mm x thickness 2mm Material AFM 34 259050 6 10 x flat gasket for the corrugated tubes outside 30mm x inside 21mm x thickness 2mm Material AFM 34 259050 7 When ordering spare parts please state the compu...

Страница 16: ...tions 14 Pipe outlets on indoor unit spacing 13 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 Spare parts 15 W Warranty 5 ...

Страница 17: ...17 ...

Страница 18: ...REMKO WKF compact 18 ...

Страница 19: ......

Страница 20: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...

Отзывы: