background image

Safety and

usage instructions

1.1  General safety notes

Carefully read the operating manual before com-

missioning the units for the first time. It contains

useful tips and notes such as hazard warnings to

prevent personal injury and material damage.

Failure to follow the directions in this manual not

only presents a danger to people, the environment

and the system itself, but will void any claims for

liability.

Keep this operating manual and the refrigerant

data sheet near to the units.

1.2  Identification of notes

This section provides an overview of all important

safety aspects for proper protection of people and

safe and fault-free operation.The instructions and

safety notes contained within this manual must be

observed in order to prevent accidents, personal

injury and material damage.

Notes attached directly to the units must be

observed in their entirety and be kept in a fully

legible condition.

Safety notes in this manual are indicated by sym-

bols. Safety notes are introduced with signal words

which help to highlight the magnitude of the danger

in question.

 DANGER!

Contact with live parts poses an immediate

danger of death due to electric shock. Damage

to the insulation or individual components may

pose a danger of death.

 DANGER!

This combination of symbol and signal word

warns of a situation in which there is immediate

danger, which if not avoided may be fatal or

cause serious injury.

 WARNING!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may be fatal or cause

serious injury.

 CAUTION!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause injury or mate-

rial and environmental damage.

 NOTICE!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause material and

environmental damage.

This symbol highlights useful tips and recom-

mendations as well as information for efficient

and fault-free operation.

1.3  Personnel qualifications

Personnel responsible for commissioning, opera-

tion, maintenance, inspection and installation must

be able to demonstrate that they hold a qualifica-

tion which proves their ability to undertake the

work.

1.4  Dangers of failure to observe

the safety notes

Failure to observe the safety notes may pose a risk

to people, the environment and the units. Failure to

observe the safety notes may void any claims for

damages.

In particular, failure to observe the safety notes

may pose the following risks:

n

The failure of important unit functions.

n

The failure of prescribed methods of mainte-

nance and repair.

n

Danger to people on account of electrical and

mechanical effects.

1.5  Safety-conscious working

The safety notes contained in this manual, the

existing national regulations concerning accident

prevention as well as any internal company

working, operating and safety regulations must be

observed.

 

 

 

REMKO heater for anti-freeze protection

 

 

4

Содержание SQW 400

Страница 1: ...Operating manual Read the instructions prior to performing any task REMKO heater for anti freeze protection 0168 2017 08 Edition 1 en_GB ...

Страница 2: ... these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Страница 3: ...fety instructions for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transportation and packaging 5 1 12 Environmental protection and recycling 6 2 Technical data 7 2 1 Unit data and features 7 2 2 Unit dimensions 8 2 3 Heating capacity characteristic curve 9 3 Unit description 10 4 E...

Страница 4: ... cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal word warns ...

Страница 5: ...s Modifications or changes to units and components are not permitted and may cause malfunctions Safety devices may not be modified or bypassed Original replacement parts and accessories authorised by the manufactured ensure safety The use of other parts may invalidate liability for resulting consequences 1 9 Intended use The heater for anti freeze protection is used to control the temperature of t...

Страница 6: ... sustaining raw mate rials Only dispose of packaging at approved collection points Disposing of the units and their components For the manufacture of the units and components only recyclable materials have been used Help protect the environment by ensuring that the units or components for example batteries are not dis posed of in household waste but only in accord ance with local regulations and i...

Страница 7: ...ee blowing 45 m3 h AC 230 V service life 40 000 h at 40 C 104 F Connection 2 pole dual press clips for rigid wiring 2 5 mm2 stranded wire with wire end ferrules 1 5 mm2 Housing Plastic per UL94 V 0 black Fastening Screw lugs Ø 5 5 mm tightening torque 2 Nm max use washers Installation orientation Air flow direction vertical air outlet at top and horizontal Dimensions 105 x 115 x 108 mm Weight kg 0...

Страница 8: ...5 108 103 103 45 C D Fig 1 Dimensions A Front view B Side view C Plan view D Rear view We reserve the right to modify the dimensions and design as part of the ongoing technical development process REMKO heater for anti freeze protection 8 ...

Страница 9: ...2 3 Heating capacity characteristic curve A B W C Fig 2 Heating capacity A Heating capacity B Temperature 9 ...

Страница 10: ...or the power supply The heater for anti freeze protection is distin guished by a touch safe plastic housing small size and dynamic heating using PTC technology The heater for anti freeze protection is equipped with a fixed set thermostat and quick connection termi nals Connection is via external terminals The heater for anti freeze protection is mounted by means of screw lugs 1 2 1 3 Fig 3 Unit de...

Страница 11: ... Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Instructions for the operator 5 Note for inspection work 5 Note for installation work 5 Note for maintenance work 5 Personnel qualifications 4 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 T Technical data 7 U Unit description 10 Unit dimensions 8 Unit disposal...

Страница 12: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...

Отзывы: