"Settings" menu item (continued) - Expert
Level 2 menu item
Level 3 menu item
Level 4 menu item
Heating/cooling
Building adaptation
Building time constant
Standard heating load
Standard outside temp. (Heating)
Standard outside temp. (Cooling)
Max. cooling down
(outside temperature ref.)
Inertia of the heating curve
Mode
Room climate mode
Stand-By time program
Difference from heating limit
Difference from cooling limit
Screed drying function
After the screed function we recom-
mend ending this function manually
by deactivating it!
Floor screed function status
Start/end temperature
Max. temperature
Heating phase increment
Drying time
Time at high temperature
Incremental cooling phase
Time at low temperature
Floor screed function
Designation
Value range
Factory setting
Customer
system
Floor screed function
status
Activated/Deactivated
Deactivated
Start/end/max/temp.
"10 °C-50 °C"/"20 °C-50 °C"
20 °C/35 °C
Incremental heating phase
0.0 K - 10.0 K
5.0 K
Drying time
0.0 h - 192 h
24 h
Time at high temp.
0.0 h - 192 h
96 h
Incremental cooling phase
0.0 K - 10.0 K
5.0 K
Time at low temp.
0.0 h - 192 h
24 h
REMKO Smart-Control Touch
70