Technical Data 

Dimensions 

 

 

RXW 350 

RXW 480 

Operating mode 

 

Cooling and heating 

Nominal cooling capacity * 

kW 

3.49 

4.78 

Nominal heating capacity ** 

kW 

3.78 

5.17 

Operating range 

°C 

+16 to +30 

Refrigerant  R 

410A 

Circulating air volume per speed 

m³/h  

460/ 550 / 620 

Sound pressure level per speed *** 

dB(A) 

34 / 37 / 41 

37 / 41 / 44 

Power supply 

V/Ph/Hz 

230 / 1 / 50 

Protection type 

IP 

X0 

Electr. nominal power consumption cooling* 

kW 

1.07 

1.49 

Electr. nominal power consumption heating** 

kW 

1.09 

1.52 

Electr. nominal current consumption cooling 

4.91 

6.91 

Electr. nominal current consumption heating 

4.99 

Refrigerant connection injection pipe 

Inches (mm) 

1/4“ (6.35) 

Refrigerant connection suction pipe 

Inches (mm) 

Refrigerant pipe, length max. 

10 

Refrigerant pipe, height max. 

Dimensions height 

mm 

285 

 width 

mm 

830 

 depth 

mm 

205 

Weight kg 

11.0 

Serial number 

 

685... 

686... 

Ref. No. 

 

1619100 

1619110 

1/2“ (12.7) 

7.01 

480/ 560 / 620 

Room temperature DB 27, WB 19 °C; outside temperature DB 35 °C, WB 24 °C in combination with RKS 435 H or RKS 448 H 

**  Room temperature DB 20, WB 14 °C; outside temperature DB 7 °C, WB 6 °C in combination with RKS 435 H or RKS 448 H 
*** Distance 

1m 

RXW 350 / RXW 480 

830 

285 

205 

Содержание RXW 350

Страница 1: ...REMKO powerful like a bear REMKO RXW 350 480 Wall units Edition GB R05 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...nel 13 Installation 13 Electrical Connection 15 Wiring Diagram 15 Condensation Connection 15 Prior to Initial Operation 16 Initial Operation 16 Customer Service and Guarantee 17 Environment and Recycl...

Страница 4: ...ate the unit exclusively within the permissible op erating ranges Observe surrounding temperatures Make sure that the unit is kept at a safe distance from flammable objects Ensure that no foreign obje...

Страница 5: ...lect the operating mode The indoor unit has 5 modes Automatic In this mode the unit operates in cooling or heat ing mode Cooling In this mode the warm room air is cooled down to the desired temperatur...

Страница 6: ...the display no longer blinks CLOCK button Functional process CLOCK CLOCK By pressing the ON OFF button the air conditioning unit is switched on and off The settings and setting values programmed befor...

Страница 7: ...rature The desired room temperature is set in 1 C increments with the TEMP UP DN button If the temperature is 1 C above the set target temperature the indoor unit begins to cool the room air If the ro...

Страница 8: ...is button must be pressed again The swing function improves the air distribu tion in the room Functional process SWING SWING SLEEPING button With this button a program is activated that increases the...

Страница 9: ...med see CLOCK button RESET button Functional process RESET 5 sec Clock setting Shown on the display Malfunctions are shown as a code on the display of the indoor unit After the malfunction has been fi...

Страница 10: ...ecured against being inadvertently switched on System Structure The indoor unit is connected to the outdoor unit with re frigerant pipes Outdoor unit Refrigerant pipes Outdoors Indoors Condenser fan S...

Страница 11: ...the unit to start Polarity of batteries incorrect after replacement Is the polarity correct Insert batteries with the correct polarity Transmission distance too great reception blocked Is there a tran...

Страница 12: ...lectr nominal current consumption cooling A 4 91 6 91 Electr nominal current consumption heating A 4 99 Refrigerant connection injection pipe Inches mm 1 4 6 35 Refrigerant connection suction pipe Inc...

Страница 13: ...ust meet the relevant re quirements The power supply is only connected to the outdoor unit The control line to the indoor unit should be placed together with the refrigerant pipe Make sure that the el...

Страница 14: ...When assembling the unit observe the bending radii of the refrigerant pipes and never bend the hose in the same place twice This may cause the pipe to become brittle or crack 4 Remove the preinstalle...

Страница 15: ...fin exchanger of the indoor unit during cooling operation because tempera tures below the dew point are reached The indoor unit is equipped with a condensate collector and a condensation hose for the...

Страница 16: ...a tion must be performed using the certificate and must be documented Following initial operation the operator must be trained in its operation and the initial operation log given to him Prior to Init...

Страница 17: ...the guarantee becomes null and void Customer Service and Guarantee For the guarantee to be valid the purchaser or his cus tomer must completely fill out the guarantee certificate enclosed with all un...

Страница 18: ...ation Name Street Postal code country city Telephone Fax Test of cooling cycle Result Visual check Setup of outdoor unit and indoor unit 5 good 4 poor Heat exchanger insulation pipes 5 good 4 poor Ele...

Страница 19: ......

Страница 20: ...REMKO GmbH Co KG Air Conditioning and Heating Technology D 32791 Lage Im Seelenkamp 12 D 32777 Lage P O Box 1827 Phone 49 52 32 606 0 Fax 49 52 32 606 260 E mail export remko de Internet www remko de...

Отзывы: