  The units must only be operated 

in a completely assembled and 
mounted condition. 

   The units must only be opera-

ted within the specified capacity 
limits and with the approved 
operating media. 

 Safeguards, e.g. barriers must 

not be removed or rendered 
inoperational. 

  The units must only be operated 

within the specified capacity 
limits and with the approved 
operating media. 

  The air intake grilles must 

always be kept free of dirt and 
loose objects and the air outlet 
must not be closed. 

  Never insert foreign objects into 

the unit.

  The units must not be exposed 

to a direct jet of water.

  Do not operate the units in wet 

areas with high humidity (e.g. 
car wash).

  All electric cables of the units 

must be protected against da-
mage e.g. animals, etc.

Unit description

These units are stationary, indirect-
ly recirculated air cooling/heating 
units with copper/aluminium fin 
heat exchangers for connection to 
a pumped cold/ hot water system 
up to max. 90°C.

The units are in an exclusive de-
sign, compact, universal and are 
easy to install and service.

NOTE

Perfect functioning of the units 
is only ensured when the flow 
temperature at the unit inlet 
and the pump capacity cor-
respond to the selected unit 
classification.

The inner supporting unit con-
struction is made of galvanised 
sheet steel. 
The heat exchangers have copper 
tubes with aluminium fins. 
For removal of the produced 
condensate in cooling operation, 
a ready to connect condensate 
pump is provided.

For an optimal air flow, individually 
adjustable louvres are provided at 
the top of the housing and fully 
adjustable louvre segments are 
provided at the bottom.

The air discharge direction (hori-
zontal or vertical) can be individu-
ally adjusted to suit the local requi-
rements by changing the direction 
of rotation of the fan.

The plastic housing can be deta-
ched completely from the sup-
porting lower housing part by 
removing the securing clip. The 
integrated securing strips prevent 
the cover from falling.

The plastic housing of the units is 
made of self-extinguishing material 
(fire class V-0).

The heaters comply with the basic 
health and safety requirements of 
the pertinent EU regulations and 
are easy to operate.

The units are suitable for heating/
cooling rooms with high or low 
ceilings and where special impor-
tance is attached to exclusivity.  

For example in large rooms such 
as:

   Exhibition halls

   Sales rooms

  Shopping centres

   Business premises

   Warehouses

   Production halls

   Foremen’s offices

   Large entrance areas

The units must be mounted hori-
zontally on ceilings or roof struc-
tures.

The units are fitted with an aero-
dynamic, powerful two-speed axial 
flow fan with 400V/50Hz external 
rotor motor as standard. 

Help save on energy consump-
tion in stand-by mode! If the 
device, system or component 
is not in use, we recommend 
disconnecting the power sup-
ply. Components with a safety 
function is excluded from our 
recommendation!

      TIP

Содержание PWL 101-3

Страница 1: ...Edition GB Vo6 REMKO PWL Ceiling mounted air unit Heating Cooling Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...ta PWL 201 203 16 Rating tables Technical data PWL 301 303 18 Intended use 20 Customer service and warranty 20 Environmental protection and recycling 20 Exploded view 21 Spare parts list 21 Legend Ope...

Страница 4: ...s length width height Required air change Required room temperature Required heating medium tem perature for flow and return The air inlet temperature of the units should not be below 34 C and not abo...

Страница 5: ...r removal of the produced condensate in cooling operation a ready to connect condensate pump is provided For an optimal air flow individually adjustable louvres are provided at the top of the housing...

Страница 6: ...o an air outlet temperature of 8K below room temperature and ideal prima ry air flow conditions Maximum mounting heights and operating limits The maximum mounting heights depend on the maximum range a...

Страница 7: ...using This prevents persons being expo sed to a direct air stream Rooms with low ceilings horizontal blowing direction Rooms with low ceilings horizontal blowing direction Rooms with high ceilings ver...

Страница 8: ...day night control etc can always be connected per control unit Terminals in the unit Fuse protection in the supply to the control unit must be in compli ance with the applicable regulati ons The conn...

Страница 9: ...tion To prevent frost damage anti frost protection must be provided at temperatures below 0 C Where systems in rooms at risk from frost are not used for ex tended periods under no circum stances must...

Страница 10: ...ool down Cleaning the units The surfaces of the units must be cleaned only dry or with a moist cloth and a small amount of soap solution if necessary Under no circumstances use high pressure cleaners...

Страница 11: ...hydraulic con nection 4 Remove the bottom support plate 6 screws 5 Remove the support plate with fin exchanger downwards 6 Carefully re install the replace ment heat exchanger and all further componen...

Страница 12: ...he produced con densate in cooling operation The pump is a self priming rotary diaphragm pump The condensate is pumped out via a flexible PVC condensate hose with an internal diameter of 6 mm Safety i...

Страница 13: ...red Unit dimensions Dimen sions PWL 101 103 HK PWL 201 203 HK PWL 301 303 HK A 985 mm 1084 mm 1178 mm B 632 mm 963 mm 1043 mm C 229 mm 229 mm 229 mm D 989 mm 1073 mm 1160 mm H 465 mm 485 mm 504 mm Con...

Страница 14: ...8 34 11 6 36 16 4 41 14 2 42 20 6 9 30 6 1 31 11 0 37 10 0 39 14 2 45 12 3 44 70 50 C 0 12 0 16 10 7 18 19 5 28 17 8 31 25 4 37 22 0 40 5 10 8 20 9 7 21 17 6 30 16 1 33 23 0 39 19 9 42 10 9 7 24 8 6 2...

Страница 15: ...0 24 54 4 5 23 55 7 8 20 67 7 0 19 69 10 5 17 77 9 3 16 79 32 40 5 9 25 55 5 3 25 56 9 2 21 67 8 3 20 69 12 3 18 77 10 8 16 79 8 14 C 24 60 2 5 21 71 2 3 21 72 4 1 19 80 3 7 18 81 5 9 17 86 5 3 16 88...

Страница 16: ...7 5 33 15 5 34 22 5 38 19 8 40 20 8 4 28 7 5 29 15 1 35 13 4 37 19 4 40 17 1 42 70 50 C 0 14 5 13 13 0 14 26 6 25 23 7 27 34 5 34 30 4 36 5 12 9 17 11 6 18 24 1 28 21 4 30 31 2 36 27 4 38 10 11 4 21 1...

Страница 17: ...74 12 3 17 76 32 40 6 4 27 53 5 8 26 54 12 3 22 65 11 2 21 67 16 1 19 74 14 4 18 76 8 14 C 24 60 2 2 22 68 2 0 22 69 5 6 19 79 5 1 19 80 7 2 18 85 6 5 17 86 26 50 2 8 23 59 2 5 23 60 5 9 20 73 5 2 20...

Страница 18: ...9 30 14 9 33 29 2 37 16 5 43 20 10 9 28 8 2 29 17 8 33 12 8 36 25 2 39 14 3 45 70 50 C 0 18 8 12 14 3 15 31 0 21 22 3 26 44 8 32 25 6 41 5 16 9 16 12 7 19 27 8 24 20 0 29 40 5 34 23 2 43 10 14 9 20 1...

Страница 19: ...8 15 81 32 40 8 3 27 52 6 5 26 55 13 0 23 63 10 0 22 68 29 1 19 73 12 7 16 81 8 14 C 24 60 3 0 22 68 2 3 21 70 8 4 17 81 3 6 19 79 9 4 18 84 6 0 16 89 26 50 3 7 23 58 2 8 23 61 8 5 18 74 4 4 20 70 9 9...

Страница 20: ...a valuable contribution towards waste reduction and the conservation of raw materials Only dispose of packaging materi al at the facilities provided Disposal of old unit The production of our units is...

Страница 21: ...2 speed 1110706 1110717 1110728 6 Top support plate 1110707 1110718 1110729 7 Bottom support plate 1110708 1110719 1110730 8 Side air grille 1110709 1110720 1110731 9 Bottom air segment 1110710 11107...

Страница 22: ...With the external rotor motor the impeller with its drive motor is an optimal unit for applications in the field of heating and ventilation The axial flow fan is statically and dynamically balanced Th...

Страница 23: ...750 920 750 Air capacity Bg 1 m3 h 2030 1685 3110 2580 4300 2650 Air capacity Bg 2 m3 h 1960 1610 2900 2400 4150 2400 Air capacity Bg 3 m3 h 1885 1530 2580 2350 3900 1710 Sound pressure level LpA 1m 1...

Страница 24: ...t as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is q...

Отзывы: