2
Technical data
2.1 Unit data
Series
MXT 263
MXT 353
MXT 523
Operating mode
Wall chest for inverter multisplit outdoor units for
cooling and heating
Nominal cooling output
1)
kW
2.6
3.5
5.3
Nominal heat capacity
2)
kW
2.9
3.5
5.3
Application area (room volume), approx.
m
3
80
110
160
Adjustment range room temperature
°C
+17 to +30
Operating range
°C/r.H.
%
+17 to +32 / 35-65
Refrigerant
4)
R 410A
Max. operating pressure
kPa
4200
Air flow volume per level
m³/h
450/580/680
360/470/550
520/650/740
Sound pressure level per speed setting
3)
dB (A)
35/40/45
35/41/47
39/44/48
Sound power level max.
dB (A)
56
58
59
Power supply
V / Ph /
Hz
230 / 1~ / 50
Enclosure class
IP
X 0
Electrical rated power consumption, cooling
1)
W
30
40
50
Electrical rated power consumpt., heating
2)
W
36
48
58
Electrical rated current consumpt., cooling
1)
A
0.13
0.17
0.22
Electrical rated current consumpt., heating
2)
A
0.16
0.21
0.25
Refrigerant connection
Injection pipe
Inches
(mm)
1/4 (6.35)
1/4 (6.35)
1/4 (6.35)
Refrigerant connection
Suction pipe
Inches
(mm)
3/8 (9.52)
3/8 (9.52)
1/2 (12.70)
Condensate drainage connection
mm
22
7
Содержание MXT 263
Страница 39: ......