background image

Electrical connection diagram and choice of unit

Electrical circuit diagram

MXD 200 to 520

Choice of unit

Outdoor component

Indoor unit

Mains cable

Neutral conductor

Neutral conductor 

Exterior conductor

Exterior conductor 

230 V~, 
50 Hz, 
L1 / N / PE

Data cable 

N

L1

PE

L

N

N

L

S

PE

S

PE

Earth conductor

Blau

Blau

Blau

Blau

Blau

Blau

Bl

a

u

Kompressor

Rot

Schwarz

Gelb

Gelb

Schwarz

Rot

Weiß

Rot

Rot

Rot

Sc

hw

a

rz

G

e

lb

G

ra

u

Filter

Schwarz

Rot

Rot

Schwarz

Schwarz

Ye

llo

w

/G

re

e

n

Yellow/Green

Ye

llo

w

/G

re

e

n

Schwarz

Rot

Sc

hw

a

rz

Br

a

un

Br

a

un

Weiß

Weiß

Weiß

Weiß

Rot

Rot

Rot

Rot

Rot

Orange

Rot

Schwarz

U

W

V

U

V

W

P

N

IPM

10PIN

W V U

L202

IPM

EEW

T5

CN4

CN12

CN5

CN5

C

N

16

C

N

11

C

N

1

CN2

Trans.

Trans.

C

N

20

C

N

27

C

N

28

C

N

9

Hochdruckschalter

Niedrigdruckschalter

R2503

P-3

P-4

P-5

P-6

P-2

3

C

N

3

R1815B

R1

32

5C

C

N

14

C

N

15

C

N

13

C

N

12

C

N

7

C

N

5

C

N

6

C

N

4

C

N

8

C

N

10

C

N

9

Blau

Ventilator

CN1

CN2

L

N

L

N

P-1

L

H

Sensor  Heißgas

Sensor  Außentemperatur

Sensor  Austritt 
Verflüssiger

Elektronisches
Expansionsventil

Leistungsplatine

zum  Innengerät

Steuerleiter

Hauptplatine

St

e

c

kv

e

rb

in

d

e

r

Steckverbinder

Connecting MVT 600 DC / MVT 900 DC  

MVT 950 DC / MVT 1050 DC

DIP-switch 1 (SW1)

DIP-switch 2 (SW2)

Choice of temperature

Choice of unit

Unit

ON

1 2

0 K

ON

1 2

 MXD 200

ON

1 2

2 K

ON

1 2

 MXD 260

ON

1 2

4 K

ON

1 2

 MXD 350

ON

1 2

6 K

ON

1 2

 MXD 520

DIP-switch 1 

(SW1)

DIP-switch 2 

(SW2)

REMKO MXD

22

Содержание MXD 200

Страница 1: ...Issue GB W06 REMKO MXD MXD 200 MXD 260 MXD 350 MXD 520 Ceiling cassette Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...tal protection and recycling 4 Warranty 4 Intended use 5 Transport and packaging 5 Equipment description 5 Combinations 6 7 Operation 8 14 shut down 15 Care and maintenance 15 16 Troubleshooting and c...

Страница 4: ...ing some parts of the equipment can result in burns or other injury Installation repair and mainte nance work may be carried out only by authorised specialists Visual inspections and cleaning can be p...

Страница 5: ...con nect the indoor unit to the outdoor unit Outdoor component System layout Condenser fan Outdoor area Injection line Suction line Control cable Condensation line Indoor area Condensation line Indoor...

Страница 6: ...Combination 1 Combination 2 Combination 3 Two indoor units Combination 4 Combination 5 Combination 6 Combination 8 Combination 9 Three indoor units Combination 13 Combination 14 Combination 15 Combin...

Страница 7: ...0 One indoor unit Combination 1 Combination 2 Combination 3 Combination 4 Two indoor units Combination 5 Combination 6 Combination 7 Combination 8 Combination 9 Combination 10 Combination 11 Combinati...

Страница 8: ...ly operated Faults are indicated in code see chapter Troubleshooting and Customer service CAUTION Immediately replace flat batter ies with a new set otherwise there is a risk of leakage It is recommen...

Страница 9: ...e left LOCK button prevents subsequent operation the right RESET button resets the display Buttons on the remote control ON OFF button Press this button to start the unit MODE button Use this button t...

Страница 10: ...ating cooling and air circulation modes The nominal temperature can be preselected and is then applied in automatic mode The fan speed is auto matically adapted to the given circumstances AUTOMATIC MO...

Страница 11: ...the vaporiser is lower The excess moisture in the air is condensed by the vaporiser the room is dehumidified The fan speed should be set to automatic in order to achieve a maximum level of dehumidifi...

Страница 12: ...re and the actual room temperature If there is a large difference a higher cooling output is produced If there is a small difference a lower cooling output is produced This serves to maintain the air...

Страница 13: ...ction of the air discharge fins can be adjusted with this button The air distribution in the room is improved by the swing function In order to adjust the aim of the air discharge fins to a particular...

Страница 14: ...activation delay Activation delay TIMER OFF button switch off delay CANCEL delete timer program Switch off delay Time stored TIMER ON TIMER ADJUST TIMER ADJUST TIMER ADJUST OK TIMER OFF CANCEL CLOCK 2...

Страница 15: ...and other deposits Clean the unit using a damp cloth Do not use any caustic abrasive or solvent based clean ing products Do not use a jet of water Clean the fins on the unit prior to long shutdown per...

Страница 16: ...g agents To do so turn the dirty side downward Fig 3 6 When using water allow the filter dry out properly in air before replacing it in the unit 7 Carefully insert the filter Make sure it is seated co...

Страница 17: ...terference Signal is not transmitted when interference sources are operational Button in remote control jammed two buttons pressed at same time Does the Send symbol appear on the display Release the b...

Страница 18: ...n leads flashes flashes E0 EEPROM error Check EEPROM flashes On Inverter module shutdown flashes Condensation pump float switch faulty tripped Contact specialist dealer flashes On E4 Outdoor temp sens...

Страница 19: ...re and never kink or compress the refrigerant pipes Only use the union nuts for the refrigerant pipes included in the delivery and remove them shortly before connecting the refrigerant pipes Establish...

Страница 20: ...it a trap to prevent any unpleasant odours When operating the unit at outdoor temperatures below 4 C ensure the condensation pipe is laid to protect it against frost If necessary fit supplementary pip...

Страница 21: ...or unit contains a data cable which makes communication between the indoor unit and the outdoor unit possible This is used for controlling cooling and heat ing output and for forwarding fault indicati...

Страница 22: ...Schwarz U W V U V W P N IPM 10PIN W V U L202 IPM EEW T5 CN4 CN12 CN5 CN5 CN16 CN11 CN1 CN2 Trans Trans CN20 CN27 CN28 CN9 Hochdruckschalter Niedrigdruckschalter R2503 P 3 P 4 P 5 P 6 P 2 3 CN3 R1815B...

Страница 23: ...parts Familiarise the operator with the system 3 Measure and record all the required values in the commis sioning report and check the safety functions 4 Check the control system for the unit using th...

Страница 24: ...REMKO MXD 24 Notes...

Страница 25: ...Condensation pump cpl 1111037 1111037 1111037 1111037 9 Fan wheel 1111038 1111038 1111038 1111038 10 Vaporiser fan motor 1111039 1111039 1111039 1111039 11 Control board 1111040 1111040 1111040 11110...

Страница 26: ...ing range room volume approx m 60 80 110 160 Room temperature adjustment range C 17 to 30 Operating range C 17 to 32 Refrigerant R 410A 4 Operating pressure max per cooling circuit kPa 4200 4200 Air f...

Страница 27: ...Seelenkamp 12 D 32791 Lage Equipment machinery Implementation Multi inverter ceiling cassette Series Model REMKO MXD 200 MXD 260 MXD 350 MXD 520 Series Class Number 770 771 772 778 Applicable regulat...

Страница 28: ...our customers on air conditioning and heating technology Customer Service Our equipment operates pre cisely and reliably However in the event of a fault REMKO customer service is quickly at the scene...

Отзывы: