background image

Safety Instructions 

 
Extensive tests have been conducted on the material, 
functionality and quality of the REMKO portable air con-
ditioner to ensure that it is a high-performance unit with 
a long service life. 

Hazards may nevertheless arise if the unit is used by 
persons not familiar with its operation or if the unit is not 
used for its intended purpose. 

Please make sure to follow these safety instructions. 

The unit is not suitable for outdoor operation. 

Do not set up or operate the unit in rooms suscepti-
ble to explosions. 

Ensure that the unit is set up at a safe distance from 
flammable materials. 

Do not set up or operate the unit if the atmosphere is 
contaminated by oil, sulfur or salt. 

Do not set the unit up near curtains or drapes.     

Minimum distance of 50 cm.

 

Ensure that the air intake and outlet openings are al-
ways clear of foreign objects. 

Ensure that the air conditioner is securely placed on 
a level surface. 

The unit may only be operated in an upright position. 

Do not insert any foreign objects into the air intake or 
outlet openings. 

Do not place any heavy or  warm objects on top of 
the unit. 

Do not expose the unit to direct streams of water. 

Operate the unit only within its permissible operating 
ranges.      

Pay attention to surrounding temperatures.

 

This unit may only be connected to a correctly in-
stalled, grounded and fused plug socket.    

230V / 50Hz, fuse 10A. 

When unplugging the unit, do not pull the power too 
forcefully or bend it too much.     

This may result in damage to the cable! 

Do not move the unit while in operation. Wait at least 
5 minutes before starting the unit after it has been 
moved.      

This protects the unit from damage

Switch the unit off by pressing the “Power” button. 
Do not switch the unit off by unplugging the power 
cord. 

Do not transport the unit during operation. 

Do not place the unit on its side. 

Protect all electrical cables from being damaged, for 
example, by animals. 

Make sure that all extension cables are suitable in 
terms of capacity, length and intended use. 

Do not lay any lines under carpets. 

Never operate the unit without the air filter! 

Never aim the air current directly at people! 

Never open the unit housing!  

This may cause an electric shock.

 

Work on the cooling system and on the electrical 
equipment may only be performed by an authorised 
service centre. 

Transport and Packaging 

 
All units are subject to continuous quality control and 
are carefully packaged before being sent. 

The device is shipped in a stable transport box made of 
cardboard. Please examine the unit when it is delivered. 

Make note of any damage or missing parts on the ship-
ping bill and inform the shipping company and your con-
tract partner. No liability is assumed for subsequent 
claims. 

Please observe the following for transport: 

Before transporting the unit, switch it off on the con-
trol panel and unplug the power cable. 

The unit may only be transported in an upright posi-
tion. 

The unit is equipped with wheels and two handles to 
make transport easier.  

Excess condensation is collected in the internal tank 
of the unit. We recommend removing this water prior 
to transport via the drain at the back of the unit. 

Operation/handling which does not comply with 
these instructions is prohibited!  
In cases of non-compliance, we assume no liability 
and the guarantee becomes null and void. 

G

 

Содержание MTK 260

Страница 1: ...Operation Technology Spare Parts REMKO powerful like a bear REMKO MKT 260 Portable Room Air Conditioner Edition GB P04...

Страница 2: ......

Страница 3: ...erations Portable Room Air Conditioner REMKO MKT 260 Operating Instructions Contents Page Safety Instructions 4 Transport and Packaging 4 Description of Device 5 Operation 5 Prior to Initial Operation...

Страница 4: ...t 5 minutes before starting the unit after it has been moved This protects the unit from damage Switch the unit off by pressing the Power button Do not switch the unit off by unplugging the power cord...

Страница 5: ...hen tempera tures in the room are high it is not practical to adjust the unit to the lowest possible target temperature The unit has been designed for automatic universal smooth air dehumidification I...

Страница 6: ...activated Control panel 4 3 2 1 7 11 10 6 12 5 8 9 5 Buttons Up Down Timer Temp Adjust These buttons can be used to select the desired tar get temperature in the cooling and dehumidifying op erating...

Страница 7: ...ol lect the water that drains out 4 Then replace the plug 1 5 V 1 5 V 1 5 V 1 5 V 2 Place the batteries in the slot making sure that the polarity is correct Use the labelling in the slot 3 Close the b...

Страница 8: ...It is possible to guide the flat nozzle through the open window and se cure it firmly using straps and suc tion devices The flat nozzle can also be hung through the partially opened win dow 2 With a f...

Страница 9: ...s not overflow This can result in water damage 6 After the dehumidifier operation is complete reinsert the plug of the condensation drain Keep in mind that if there is no plug or it is inserted in cor...

Страница 10: ...aners or polish to clean the unit These can damage the surface Only use lukewarm water Maximum 40 C warm Make sure that no moisture gets into the unit Never spray water or other fluids into the unit T...

Страница 11: ...Has the minimum distance of 50 cm been maintained Maintain minimum distance Windows and doors open thermal load increased Has something been changed in the design or application Close windows and doo...

Страница 12: ...ed View We reserve the right to make changes to dimensions and design in the interest of technical progress 1 2 3 4 5 6 7 8 14 9 10 11 12 13 15 37 35 36 16 23 25 32 21 17 30 20 22 27 26 33 29 28 18 19...

Страница 13: ...6329 30 Reception board 1106330 31 Recessed grip 1106331 32 Air filter 1106332 33 Remote control 1106333 34 Exhaust hose cpl 1106334 35 Exhaust hose 1106335 36 Connection adapter 1106336 37 Window noz...

Страница 14: ...is being re paired Both the refrigerant and the system parts are subject to special requirements for disposal The refrigerant in use is a safety refrigerant This means that should damage occur the qua...

Страница 15: ...table insulation material 3 Place bricks around the telescope pipe in the core hole so that it is aligned with both sides of the wall Safety guard Back pressure flap Sealing cap Telescope pipe 4 Attac...

Страница 16: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 0 52 32 606 0 Fax 0 52 32 606260 E Mail info remko de Internet www remko de...

Отзывы: