1.7  Safety instructions for the oper-

ator

The operational safety of the units and compo-

nents is only assured providing they are used as

intended and in a fully assembled state.

n

This unit may only be installed and operated as

described in this manual.

n

Independent conversion and/or modification of

any kind is strictly prohibited.

n

Children must not be left unsupervised when

close to the unit.

n

For safety reasons, people with mental, phys-

ical or other health limitations must not operate

this unit unattended.

n

The unit is not permitted to be operated with

damaged cables. The unit must be repaired by

a specialist immediately.

n

The unit may only be operated via a power

supply with grounding.

n

The use of extension cables is not recom-

mended.

n

The air filter must be cleaned at intervals of no

more than 2 weeks.

n

The unit is not permitted to be operated in the

vicinity of heat sources.

n

The unit must be transported upright. Residue

from the condensate must be drained off

before transport. The unit must be stood

upright for 1 hour prior to commissioning.

n

Operating the units in rooms with potential igni-

tion sources (naked flames, gas or electrical

heaters, fireplaces) is prohibited.

n

The unit may only be installed, operated and
stored in rooms larger than 14.4 m

2

.

n

Protective covers (grilles) over moving parts

must not be removed from units that are in

operation.

n

Do not operate units or components with

obvious defects or signs of damage.

n

Contact with equipment parts or components

can lead to burns or injury.

n

The units and components must not be

exposed to any mechanical load, extreme

levels of humidity or extreme temperatures.

n

Never drill through the housing cover or have

the unit come into contact with fire.

n

Rooms in which refrigerant may escape must

be adequately aerated and ventilated. Other-

wise there is danger of suffocation.

n

All housing parts and unit openings, e.g. air

inlets and outlets, must be free from foreign

objects, fluids or gases.

n

The local room air conditioners are designed

for flexible use in living and work spaces. Year-

round operation is not recommended. Use in

server rooms is prohibited.

n

Do not leave the units running for an extended

period unsupervised.

Improper use can cause serious damage to the

unit.

Read this manual carefully before commissioning!

The unit and in particular the control panel must

not come into contact with water.

Never cover the air inlets and outlets.

Do not allow children to play with the unit

Do not stand or sit on the unit.

 

 

 

REMKO MKT ECO series

 

 

6

Содержание MKT 255 ECO S-Line

Страница 1: ...on instructions Read the instructions prior to performing any task REMKO MKT ECO series MKT 255 ECO MKT 255 ECO S Line MKT 295 ECO MKT 295 ECO S Line Local room air conditioner in compact design 0233...

Страница 2: ...these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modificati...

Страница 3: ...lation maintenance and inspection 7 1 9 Unauthorised modification and changes 9 1 10 Intended use 10 1 11 Warranty 10 1 12 Transport and packaging 10 1 13 Environmental protection and recycling 10 2 T...

Страница 4: ...n Repairs may only be carried out by authorised and certified specialist personnel n The unit must not be covered with plastic sheets n This unit must be disposed of professionally in accordance with...

Страница 5: ...RNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word...

Страница 6: ...ters fireplaces is prohibited n The unit may only be installed operated and stored in rooms larger than 14 4 m2 n Protective covers grilles over moving parts must not be removed from units that are in...

Страница 7: ...oms with limited space is prohibited Ensure that sufficient space is available at the work place Ensure that the ambient conditions are suitable for working with combustible refriger ants n Identify r...

Страница 8: ...voided the critical points of potential refrig erant leakages must be checked using a leak detector The following notes must be observed when working on electronic components if the housing is changed...

Страница 9: ...ss must often be repeated until there is no more refrigerant in the system After the last flushing the system must be brought to the ambient pressure in order to start work The flushing process is ind...

Страница 10: ...nclude special agreements beyond these conditions In this case contact your contractual partner in the first instance 1 12 Transport and packaging The devices are supplied in a sturdy shipping con tai...

Страница 11: ...ting pressure cooling cycle kPa 1160 4120 Air flow volume per stage m3 h 230 290 325 260 330 340 Sound pressure level per stage 2 dB A 49 50 51 Sound power level max dB A 65 Power supply V Ph Hz 230 1...

Страница 12: ...densate pump located in the unit the con denser evaporates the condensate and discharges it to the outside via the exhaust air hose The unit filters and dehumidifies the air thereby creating a comfort...

Страница 13: ...Y or circulated air mode FAN The LEDs indicate the selected operating mode 3 FAN speed key With this key it is possible to set the fan speed and therefore the air flow It is possible to select between...

Страница 14: ...ith the unit switched on any change to the settings will be automatically transferred to the room air conditioner The proper receipt of data will be acknowledged with an audible beep n To operate the...

Страница 15: ...r supply must be of a sufficient cable size and must only be used fully rolled out Fig 5 Power supply n Check whether the stopper in the condensate drain is present and correctly installed There is a...

Страница 16: ...t air to the outdoor area or to outdoors Exhaust air routing variants You can route the exhaust air out of the building as follows Via a flat nozzle The flat nozzle supplied can be used in various dif...

Страница 17: ...evaporator fins This will transport the remaining moisture out of the unit and this will avoid unpleasant odours when the unit is re commissioned 2 Switch the unit off with the I O key pull out the po...

Страница 18: ...N1 CN2 L N PE M M M A 2 1 4 3 5 6 3 7 8 Fig 12 Electrical wiring diagram A Power supply 1 Infrared receiver 2 Liquid level switch 3 Temperature probe 4 Condensate pump 5 Fan motor evaporator 6 Compres...

Страница 19: ...The unit does not work or works at reduced cooling capacity Exhaust air hose kinked extended routed downwards or blocked Ensure that there is a clear path for the exhaust air Filter contamination inl...

Страница 20: ...n is not correctly inserted or is damaged Insert stopper correctly or replace if necessary Error indication by code Error code Error description Error elimination E1 Ambient temperature probe defec ti...

Страница 21: ...ou take out a mainte nance contract with an appropriate specialist firm This enables you to ensure the operational reli ability of the plant at all times Filter cleaning The unit is equipped with an a...

Страница 22: ...11 Exploded view of the unit and spare parts list 11 1 Exploded view of the unit MKT 255 ECO MKT 255 ECO MKT 295 ECO MKT 295 ECO Fig 14 Exploded view REMKO MKT ECO series 22...

Страница 23: ...er stopper 4 Sealing cap 5 Condensate pump 6 Protective cap 7 Condensate tray cover 8 Protection grid hose connection 9 Exhaust air hose connection nozzle 10 Liquid level switch 11 Compressor 12 Vibra...

Страница 24: ...41 Display board 42 Operating panel 43 Display circuit board 44 Display board cover 45 Housing front 46 Board housing cover 47 Board housing 48 Control board 49 Compressor capacitor 50 Capacitor compr...

Страница 25: ...ew 22 Exploded view of the unit 22 I Installation 15 M Maintenance 21 O Operation Control panel 13 R Recirculated air filter 15 S Safety Dangers of failure to observe the safety notes 5 General 4 Iden...

Страница 26: ...REMKO MKT ECO series 26...

Страница 27: ......

Страница 28: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: