Commissioning

Before every commissioning the air inlet and outlet

openings should be checked for foreign bodies and

the air inlet filter must be checked for dirt. Blocked

or soiled grills and filters must be cleaned immedi-

ately, see "Care and maintenance" chapter.

Cooling mode

1.

Switch the unit on with the "I/O" key.

2.

Select cooling mode with the "MODE" key.

3.

Set the desired target temperature with the

"THERMO/TIMER CONTROL" keys. The

selected target temperature will be shown in

the display. If the fan speed selected is too

large or too small then this can be adjusted

with the "FAN" key.

Recirculation mode

1.

Switch the unit on with the "I/O" key.

2.

Select recirculation mode with the "MODE"

key.

Shutdown

 NOTICE!

Never switch off the equipment by pulling out

the mains plug.

Temporary shutdown

If it is planned to shut down the unit for longer

periods e.g. during the winter, proceed as follows:

1.

Let the unit run in recirculating operation for

ca. 2 hours in order to dry the surfaces of the

evaporator fins. This will transport the

remaining moisture out of the unit and this

will avoid unpleasant odours when the unit is

re-commissioned.

2.

Switch the unit off with the "I/O" key, pull out

the power plug and wind up the power

supply. Ensure that the cable is not kinked or

too severely bent. The line can be fastened

to the rear of the unit.

3.

Place a suitable container underneath the

condensate drain of the internal reservoir.

The condensate drain is located on the lower

rear side of the unit.

4.

Pull out the stopper from the condensate

drain and collect the condensate that drains

out.

5.

Then insert the stopper once again. A

missing stopper or an incorrectly inserted

stopper will result in condensate leaking out

after re-commissioning.

6.

Store the unit in an upright position in a cool,

dry and dust-free location protected from

direct sunlight. Cover the unit with a synthetic

cover to protect it against dust if desired.

Permanent shutdown

The entire system should only be dismantled by a

specialist firm familiar with all environmental

aspects involved. REMKO GmbH & Co. KG or your

contractual partner will be pleased to provide a list

of refrigerant specialists in your area.

 

 

 

 

 

17

Содержание MKT 255 ECO S-Line

Страница 1: ...on instructions Read the instructions prior to performing any task REMKO MKT ECO series MKT 255 ECO MKT 255 ECO S Line MKT 295 ECO MKT 295 ECO S Line Local room air conditioner in compact design 0233...

Страница 2: ...these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modificati...

Страница 3: ...lation maintenance and inspection 7 1 9 Unauthorised modification and changes 9 1 10 Intended use 10 1 11 Warranty 10 1 12 Transport and packaging 10 1 13 Environmental protection and recycling 10 2 T...

Страница 4: ...n Repairs may only be carried out by authorised and certified specialist personnel n The unit must not be covered with plastic sheets n This unit must be disposed of professionally in accordance with...

Страница 5: ...RNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word...

Страница 6: ...ters fireplaces is prohibited n The unit may only be installed operated and stored in rooms larger than 14 4 m2 n Protective covers grilles over moving parts must not be removed from units that are in...

Страница 7: ...oms with limited space is prohibited Ensure that sufficient space is available at the work place Ensure that the ambient conditions are suitable for working with combustible refriger ants n Identify r...

Страница 8: ...voided the critical points of potential refrig erant leakages must be checked using a leak detector The following notes must be observed when working on electronic components if the housing is changed...

Страница 9: ...ss must often be repeated until there is no more refrigerant in the system After the last flushing the system must be brought to the ambient pressure in order to start work The flushing process is ind...

Страница 10: ...nclude special agreements beyond these conditions In this case contact your contractual partner in the first instance 1 12 Transport and packaging The devices are supplied in a sturdy shipping con tai...

Страница 11: ...ting pressure cooling cycle kPa 1160 4120 Air flow volume per stage m3 h 230 290 325 260 330 340 Sound pressure level per stage 2 dB A 49 50 51 Sound power level max dB A 65 Power supply V Ph Hz 230 1...

Страница 12: ...densate pump located in the unit the con denser evaporates the condensate and discharges it to the outside via the exhaust air hose The unit filters and dehumidifies the air thereby creating a comfort...

Страница 13: ...Y or circulated air mode FAN The LEDs indicate the selected operating mode 3 FAN speed key With this key it is possible to set the fan speed and therefore the air flow It is possible to select between...

Страница 14: ...ith the unit switched on any change to the settings will be automatically transferred to the room air conditioner The proper receipt of data will be acknowledged with an audible beep n To operate the...

Страница 15: ...r supply must be of a sufficient cable size and must only be used fully rolled out Fig 5 Power supply n Check whether the stopper in the condensate drain is present and correctly installed There is a...

Страница 16: ...t air to the outdoor area or to outdoors Exhaust air routing variants You can route the exhaust air out of the building as follows Via a flat nozzle The flat nozzle supplied can be used in various dif...

Страница 17: ...evaporator fins This will transport the remaining moisture out of the unit and this will avoid unpleasant odours when the unit is re commissioned 2 Switch the unit off with the I O key pull out the po...

Страница 18: ...N1 CN2 L N PE M M M A 2 1 4 3 5 6 3 7 8 Fig 12 Electrical wiring diagram A Power supply 1 Infrared receiver 2 Liquid level switch 3 Temperature probe 4 Condensate pump 5 Fan motor evaporator 6 Compres...

Страница 19: ...The unit does not work or works at reduced cooling capacity Exhaust air hose kinked extended routed downwards or blocked Ensure that there is a clear path for the exhaust air Filter contamination inl...

Страница 20: ...n is not correctly inserted or is damaged Insert stopper correctly or replace if necessary Error indication by code Error code Error description Error elimination E1 Ambient temperature probe defec ti...

Страница 21: ...ou take out a mainte nance contract with an appropriate specialist firm This enables you to ensure the operational reli ability of the plant at all times Filter cleaning The unit is equipped with an a...

Страница 22: ...11 Exploded view of the unit and spare parts list 11 1 Exploded view of the unit MKT 255 ECO MKT 255 ECO MKT 295 ECO MKT 295 ECO Fig 14 Exploded view REMKO MKT ECO series 22...

Страница 23: ...er stopper 4 Sealing cap 5 Condensate pump 6 Protective cap 7 Condensate tray cover 8 Protection grid hose connection 9 Exhaust air hose connection nozzle 10 Liquid level switch 11 Compressor 12 Vibra...

Страница 24: ...41 Display board 42 Operating panel 43 Display circuit board 44 Display board cover 45 Housing front 46 Board housing cover 47 Board housing 48 Control board 49 Compressor capacitor 50 Capacitor compr...

Страница 25: ...ew 22 Exploded view of the unit 22 I Installation 15 M Maintenance 21 O Operation Control panel 13 R Recirculated air filter 15 S Safety Dangers of failure to observe the safety notes 5 General 4 Iden...

Страница 26: ...REMKO MKT ECO series 26...

Страница 27: ......

Страница 28: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: