2
1
15
5
3
7
16
4
6
Fig. 4: Infrared remote control
Selection of the operating mode "Mode"
n
Cooling "Cool"
The unit provides room cooling. It filters and
dehumidifies the air thereby creating a comfort-
able room climate.
n
Dehumidifying "Dehumidify"
In dehumidifying mode moisture is removed
from the air in the room.
n
Ventilate "Fan"
The unit recirculates the room's air, filters it
and provides an even air flow.
Cooling mode "Cool"
1.
Attach the exhaust air hose to a wall pass-
through or window
2.
Switch the unit on with the "Power" key
1
.
3.
Press the "Mode" key
2
until the "Cool" LED
9
illuminates.
4.
Select the setting for the fan via the "Fan
speed" key
3
:
"High" highest fan speed
"Med" medium fan speed
"Low" lowest fan speed.
5.
If the "Room Temp" LED
12
illuminates the
current room temperature is shown in the dis-
play
7
.
6.
As soon as the
4
/
5
/
6
key is pressed, the
display changes over from room temperature
to target temperature (LED
13
illuminates)
and shows the desired temperature for 15
seconds.
7.
Adjust the desired room temperature via the
"Timer/Temp Adjust"
5
/
6
key. The up arrow
5
increases the setpoint shown in the dis-
play
7
, the down arrow
6
decreases the
setpoint displayed.
Dehumidifying mode "Dehumidify"
1.
Attach the exhaust air hose to a wall pass-
through or window
2.
Switch the unit on with the "Power" key
1
.
3.
Press the "Mode"
2
key until the "Dehu-
midify"
9
LED illuminates, the fan will be
automatically switched on at the "Med" fan
speed.
Ventilate mode "Fan"
1.
Switch the unit on with the "Power" key
1
.
2.
Press the "Mode" key
2
until the "Fan" LED
9
illuminates.
3.
Select the setting for the fan via the "Fan
speed" key
3
:
"High" highest fan speed
"Med" medium fan speed
"Low" lowest fan speed
4.
The room temperature is not affected and
remains constant. For this reason the "Timer/
Temp. Adjust" keys
5
/
6
cannot be used.
REMKO MKT