Recirculation mode
1.
Use the " " key to switch the unit on.
2.
Use the " " key to select recirculation mode
(a fan symbol appears in the display).
3.
Select the desired fan speed using the "
FAN
"
key.
*) When pressing the "
+
and
-
" key, the
set temperature is shown in the display on the
remote control [A].
After 5 seconds, the current room temperature is
shown again [B].
A
B
Electric auxiliary heater
The unit if fitted with an electrical heating resistor
which is used to generate additional heating
capacity if needed.
There are 3 different operating modes:
Automatic switching
The auxiliary heater switches on automatically
under the following conditions:
- The unit is in automatic mode
- The heating requirement in the room is larger
than the maximum generated power of the heat
pump via the cooling circuit
- The outside temperature is below 2 °C
Manual switching in heating mode
The auxiliary heater can be used as a "booster" in
heating mode if needed. It is manually activated/
deactivated using the
key on the remote con-
trol.
Recirculation mode with auxiliary heater
The heating can be manually activated using the
key in recirculation mode too. When the set-
point is reached, the heating switches off automati-
cally.
21