Technical data

1) Air inlet temperature TK 27 °C / FK 19 °C, medium inlet 7 °C, medium outlet 12 °C, 0% glycol concentration, max. air flow volume
2) Air inlet temperature TK 20 °C, medium inlet 45 °C, medium outlet 40 °C, 0% glycol concentration, max. air flow volume
3) Distance of 1.0 m in a 100 m

3

 space with a reverberation time of 0.3 s

Series

KWK 

130ZW

KWK 

140ZW

KWK 

200ZW

KWK 

220ZW

KWK 

280ZW

KWK 

300ZW

Operating mode

Chilled water units for partition wall and suspended ceiling installation, 2-conductor version

Rated cooling output

 

1)

kW

1.31

1.48

1.96

2.2

2.77

3.11

Rated cooling output, sensitive

 

1)

kW

1.11

1.28

1.56

1.81

2.25

2.57

Rated heating output

2)

kW

1.61

1.86

2.22

2.58

3.23

3.69

Application area (room volume), approx.

40

50

60

70

90

100

Operating range - indoor unit

°C

+15 to +35

Air flow volume per stage

m³/h

120/199/263 147/228/314 173/264/349 199/313/416

262/392/518

294/451/610

Sound pressure level per stage 

3)

dB(A)

22/31/38

24/34/42

23/32/39

25/36/43

28/35/42

28/38/45

Sound power level per stage

dB(A)

30/40/47

32/44/52

37/48/55

40/51/59

37/46/53

39/49/57

Static pressure, max.

Pa

30

30

20

30

20

40

Power supply

V/Hz

230/1~/50

Enclosure class

IP

X0

Electr. rated power consumption 

1)

kW

35

44

39

49

51

65

Electr. rated current consumption 

1)

A

0.15

0.19

0.17

0.22

0.24

0.31

Operating medium

Water; max. 35% ethylene glycol, max. 35% propylene glycol 

Operating limits, medium - cooling

°C

+4 to +18

Operating limits, medium - heating

°C

+35 to +80

Max. operating pressure, medium

kPa

600

Nominal flow rate, medium - cooling 

1)

m³/h

0.23

0.26

0.34

0.38

0.47

0.53

Nominal flow rate, medium - heating 

2)

m³/h

0.28

0.32

0.39

0.45

0.55

0.63

Rated pressure drop, internal - cooling 

1)

kPa

4.3

5.3

11.3

14.2

7.8

9.5

Rated pressure drop, internal - heating 

2)

kPa

5.3

6.8

11.8

15.3

8.9

11.2

Medium connection, inlet

Inches

1/2 female

Medium connection, outlet

Inches

1/2 female

Medium volume

l

0.6

0.6

0.9

0.9

1.1

1.1

Condensate drainage connection

mm

19

Dimensions - Height

mm

216

216

216

216

216

216

Width

mm

460

460

610

610

760

760

Depth

mm

446

446

446

446

446

446

Weight

kg

9

9

11

11

13

13

Operating weight, approx.

kg

9.6

9.6

11.9

11.9

14.1

14.1

Serial number

1710...

1711...

1712...

1713...

1714...

1715...

EDP

1662215

1662225

1662235

1662245

1662255

1662265

REMKO KWK / KWK-ZW

26

Содержание KWK 130

Страница 1: ...W KWK 140ZW KWK 200ZW KWK 220ZW KWK 280ZW KWK 300ZW KWK 360ZW KWK 420ZW KWK 590ZW KWK 680ZW KWK 740ZW KWK 870ZW Cold water wall and ceiling units Cold water wall and ceiling units for installation in...

Страница 2: ......

Страница 3: ...notes 4 Environmental protection and recycling 4 Transportation and packaging 4 Guarantee 5 Intended use 5 Unit description 5 System layout 6 Operation 7 Shutdown 7 Care and maintenance 8 9 Troublesho...

Страница 4: ...up connection and operation of the unit and its components must take place in accordance with the operating conditions stipulated in this manual and comply with all applicable local regulations Mobil...

Страница 5: ...groups using a room temperature controller or via the building management system The unit consists of a fin heat exchanger circulation fan controller and two condensate trays for horizontal and verti...

Страница 6: ...to the room air With 4 conductor systems which are used for cooling or heating in one system both a cooling capacity from a chiller and heating capacity from a separate heating system on the indoor un...

Страница 7: ...ture to extract any residual humidity from the unit 2 Shut down the system using the controller 3 Switch off the power supply to the unit 4 Check the unit for visible signs of damage and clean it as d...

Страница 8: ...nect the power supply to the unit 2 Clean the grill and cover with a soft damp cloth 3 Switch the power supply back on Air filter for indoor unit Clean the air filter at intervals of no more than 2 we...

Страница 9: ...semble the unit in reverse order Removing the KWK ZW unit cladding The cover can be removed to clean the fan To do this proceed as follows 1 Disconnect the power supply to the unit 2 Unfasten the scre...

Страница 10: ...period to pass Filter is dirty air inlet outlet opening is blocked by debris Have the filters been cleaned Clean filters Windows and doors open Heating cooling output has increased Have structural usa...

Страница 11: ...e with applicable DIN and VDE standards Always ensure the electrical cables are properly connected to the terminals Otherwise there is a risk of fire Service openings should be provided in the suspend...

Страница 12: ...ce and repair work in the suspended ceiling and to facilitate optimum air distribution for the cover Minimum clearances KWK 130 to 870 1 000 1 000 300 300 Min 100 1 000 1 000 300 0 300 50 KWK 130ZW 87...

Страница 13: ...ry A grille optically hides the opening The unit can be used with a customer supplied duct connection piece with a maximum length of 300 mm The air is introduced directly into the unit via a shadow ga...

Страница 14: ...ir outlet side located in the upper part of the unit Mark the mounting points according to the bracket s dimensions on structurally acceptable building components and secure the unit Check again that...

Страница 15: ...heat exchanger through the bypass The bypass serves to ensure the minimum medium flow rate for the chiller Valves for hydronic balancing The calculated individual pressure losses in the pipeline netw...

Страница 16: ...ht Vertical mounting The condensate drainage line can be connected at the funnel nozzle The position of the nozzle can be selected to be on the left or right The condensate drainage connection of the...

Страница 17: ...is made at the indoor unit a control line to the chiller is not necessary If a condensate pump which is available as an accessory is used in conjunction with the unit the pump switch off contact switc...

Страница 18: ...alves 4 Adjust the test pressure to at least 200 kPa 2 0 bar 5 Check the connections for leaking water after a period of at least 24 hours If leaks are visible the connection has not been properly mad...

Страница 19: ...re and record all the required values in the commissioning report and check the safety functions 5 Check the unit control system using the functions described in the Chapter Operation Final tasks Reas...

Страница 20: ...1 155 565 65 275 345 KWK 280 959 478 219 65 85 251 322 383 395 110 185 42 112 141 155 715 65 275 345 KWK 300 959 478 219 65 85 251 322 383 395 110 185 42 112 141 155 715 65 275 345 KWK 360 1109 478 21...

Страница 21: ...322 383 395 110 185 42 112 141 155 565 65 275 345 540 100 206 KWK 280 715 446 216 65 85 251 322 383 395 110 185 42 112 141 155 715 65 275 345 690 100 206 KWK 300 715 446 216 65 85 251 322 383 395 110...

Страница 22: ...o 870 2 9 6 11 10 12 4 8 3 7 5 1 No Designation KWK 360 KWK 420 KWK 590 KWK 680 KWK 740 KWK 870 1 Unit cover 1111753 1111753 1111755 1111755 1111757 1111757 2 Fin exchanger 1111761 1111761 1111762 111...

Страница 23: ...w KWK 130ZW to 870ZW No Designation KWK 360 ZW KWK 420 ZW KWK 590 ZW KWK 680 ZW KWK 740 ZW KWK 870 ZW 1 Fin exchanger 1111761 1111761 1111762 1111762 1111763 1111763 2 Fan unit complete 1112397 111239...

Страница 24: ...40 47 33 44 51 34 43 50 36 46 53 Power supply V Hz 230 1 50 Enclosure class IP X0 Electr rated power consumption 1 kW 35 44 39 49 51 65 Electr rated current consumption 1 A 0 15 0 19 0 17 0 22 0 24 0...

Страница 25: ...32 44 52 37 48 55 40 51 59 37 46 53 39 49 57 Power supply V Hz 230 1 50 Enclosure class IP X0 Electr rated power consumption 1 kW 72 92 121 145 145 179 Electr rated current consumption 1 A 0 29 0 38...

Страница 26: ...47 32 44 52 37 48 55 40 51 59 37 46 53 39 49 57 Static pressure max Pa 30 30 20 30 20 40 Power supply V Hz 230 1 50 Enclosure class IP X0 Electr rated power consumption 1 kW 35 44 39 49 51 65 Electr...

Страница 27: ...dB A 30 40 47 32 44 52 37 48 55 40 51 59 37 46 53 39 49 57 Static pressure max Pa 30 40 70 70 50 60 Power supply V Hz 230 1 50 Enclosure class IP X0 Electr rated power consumption 1 kW 72 92 121 145...

Страница 28: ...31 225 1 05 1 05 181 min 2 21 1 57 380 1 81 1 4 311 1 4 1 23 240 1 1 1 1 188 0 92 0 92 158 0 74 0 74 127 KWK 360 max 4 38 3 13 752 3 61 2 8 620 2 82 2 47 485 2 25 2 2 385 1 85 1 85 318 1 5 1 5 257 me...

Страница 29: ...7 493 7 21 3 56 610 10 3 3 75 322 3 31 4 44 381 4 39 min 1 05 180 1 28 1 52 260 2 39 1 98 340 3 75 2 45 420 5 34 2 6 223 1 73 3 07 263 2 29 KWK 360 max 2 09 359 5 04 3 02 518 9 42 3 95 677 14 8 4 87 8...

Страница 30: ...REMKO KWK KWK ZW 30...

Страница 31: ......

Страница 32: ...ield are more than just sales people above all they must be advisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in th...

Отзывы: