1.6  Safety notes for the operator

The operational safety of the units and compo-

nents is only assured providing they are used as

intended and in a fully assembled state.

n

The units and components may only be set up,

installed and maintained by qualified per-

sonnel.

n

Protective covers (grille) over moving parts

must not be removed from units that are in

operation.

n

Do not operate units or components with

obvious defects or signs of damage.

n

Contact with certain unit parts or components

may lead to burns or injury.

n

The units and components must not be

exposed to any mechanical load, extreme

levels of humidity or extreme temperature.

n

Spaces in which refrigerant can leak sufficient

to load and vent. Otherwise there is danger of

suffocation.

n

All housing parts and device openings, e.g. air

inlets and outlets, must be free from foreign

objects, fluids or gases.

n

The units must be inspected by a service tech-

nician at least once annually. Visual inspec-

tions and cleaning may be performed by the

operator when the units are disconnected from

the mains.

1.7  Safety notes for installation,

maintenance and inspection

n

Appropriate hazard prevention measures must

be taken to prevent risks to people when per-

forming installation, repair, maintenance or

cleaning work on the units.

n

The setup, connection and operation of the

units and its components must be undertaken

in accordance with the usage and operating

conditions stipulated in this manual and comply

with all applicable regional regulations.

n

Local regulations and laws such as Water

Ecology Act must be observed.

n

The power supply should be adapted to the

requirements of the units.

n

Units may only be mounted at the points pro-

vided for this purpose at the factory. The units

may only be secured or mounted on stable

structures, walls or floors.

n

Mobile units must be set up securely on suit-

able surfaces and in an upright position. Sta-

tionary units must be permanently installed for

operation.

n

The units and components should not be oper-

ated in areas where there is a heightened risk

of damage. Observe the minimum clearances.

n

The units and components must be kept at an

adequate distance from flammable, explosive,

combustible, abrasive and dirty areas or

atmospheres.

n

Safety devices must not be altered or

bypassed.

1.8  Unauthorised modification

and changes

Modifications or changes to units and components

are not permitted and may cause malfunctions.

Safety devices may not be modified or bypassed.

Original replacement parts and accessories

authorised by the manufactured ensure safety. The

use of other parts may invalidate liability for

resulting consequences.

1.9  Intended use

The purpose of the unit is to allow for operation of

the unit series RVD DC, RVT DC, RXT DC, MXD,

MXT, MVD and MVW from a remote location.

Any different or additional use is a non-intended

use. The manufacturer/supplier assumes no lia-

bility for damages arising from non-intended use.

The user bears the sole risk in such cases.

Intended use also includes working in accordance

with the operating and installation instructions and

complying with the maintenance requirements.

The threshold values specified in the technical

data must not be exceeded.

1.10  Warranty

For warranty claims to be considered, it is essential

that the ordering party or its representative com-

plete and return the "certificate of warranty" to

REMKO GmbH & Co. KG at the time when the

units are purchased and commissioned.

The warranty conditions are detailed in the "Gen-

eral business and delivery conditions". Further-

more, only the parties to a contract can conclude

special agreements beyond these conditions. In

this case, contact your contractual partner in the

first instance.

 

 

 

 

 

5

Содержание KFB 3

Страница 1: ...Assembly and operating instructions Read the instructions prior to performing any task REMKO KFB 3 Wired remote control RVD DC RVT DC RXT DC MXD MXT MVD and MVW 0061 2013 09 Edition 1 en_GB...

Страница 2: ...g inal Read these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject t...

Страница 3: ...es for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transport and packaging 6 1 12 Environmental protection and recycli...

Страница 4: ...y be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This...

Страница 5: ...ly be secured or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed fo...

Страница 6: ...on and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials Only d...

Страница 7: ...mensions height width depth mm 120 120 20 Weight kg 0 2 Max cable length m 15 Recommended cable mm2 4 x 0 5 We reserve the right to modify the dimensions and design as part of the ongoing technical de...

Страница 8: ...ure is 1 C above the desired temperature and sufficient coolant is available the indoor unit will start to cool the room air If the actual temperature falls approx 0 5 C below the set room temperature...

Страница 9: ...wired remote control The symbol appears on the display when you press the and keys simultaneously The wired remote control is now locked and is unre sponsive when keys are pressed The device no longer...

Страница 10: ...d is not affected by any sources of heat or cold 5 Make the connections in accordance with the electrical circuit diagram Electric connec tions must be carried out as fixed connec tions in accordance...

Страница 11: ...D E 3 Fig 4 Electrical wiring diagram 1 Wired remote control 2 Indoor unit 3 On site extension by way of a four core cable max 15m Colour coding Wired remote control 1 A Blue B Gray C Red D Black Col...

Страница 12: ...f a single split combination with a remote control A KFB 3 B RVT 262 DC AT C RVT 262 DC IT Variant 2 Assembly of two single split combinations with a remote control e g server room A B C B C Fig 6 Ass...

Страница 13: ...Variant 3 Assembly of a multi split combination with a remote control A C C C C B Fig 7 Assembly of a multi split combination with a remote control A KFB 3 B MVT 1051 DC C MXW 262 13...

Страница 14: ...rating range 7 Operation 8 P Power supply 7 R Recirculation mode 8 Removing the housing cover 9 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for...

Страница 15: ......

Страница 16: ...t as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is q...

Отзывы: