REMKO ELT Series

Safety notes

Always observe the respective local building code and fire prevention 
guidelines as well as the guidelines of the accident prevention and 
insurance associations when using the units.

The units have been subjected 
to extensive material, functional 
and quality inspections prior to 
delivery. However, dangers can 
arise from the units if they are used 
improperly or not as intended by 
untrained personnel!  

Please observe the following notes

  Only qualified personnel may 

  set up and install the units.

  Repairs and maintenance of the 

equipment and components 
may only be used by qualified 
personnel follow. 

  The personnel tasked with 

operating the units must check 
the units for visible defects on 
the operating and safety devices 
as well as the presence and 
function of the protective devices 
prior to starting work

Inform 

the supervisor if defects are 
discovered!

  In the event of defects that 

endanger the operational safety 
of the unit, operation must be 
discontinued immediately

  Observe the respective local 

regulations and the relevant 
electrical safety measures when 
using the units

  Maintain safety distances to 

combustible materials

  An unobstructed air inlet and air 

outlet must be guaranteed at all 
times

  The air outlet must not be 

constricted or equipped with 
pipe or hose lines

  Never insert foreign objects into 

the units

  The units must not be covered 

during operation

  Safety devices must not be 

bypassed or disabled

  The units must not be operated 

in the vicinity of bathtubs, 
showers, swimming pools etc.

  The units must not be operated 

directly below a wall socket

  The units must not be exposed 

to direct jets of water 
e.g. 

pressure washers etc.

  Never allow water to enter the 

units

  The units must not be installed 

or operated in potentially 
flammable or explosive 
environments

   The units must not be installed 

or operated in atmospheres 
containing oil, sulphur or salt

  All electrical cables for the 

units must be protected against 
damage, even damage caused 
by animals

Unit description

The units are portable electric 
heating units for industrial 
applications.  
The units are operated exclusively 
with electric power and have been 
designed in such a way that they 
can be used fully automatically, 
universally and in a straightforward 
manner.

The units are equipped with 
specially enclosed electric heating 
resistors, low noise and low-
maintenance axial fans, a safety 
and aftercooler thermostat, an 
integrated room thermostat and 
a power supply cable.

The units conform to the 
fundamental health and safety 
requirements of the appropriate 
EU stipulations.

The units are dependable and offer 
ease of operation.

The units may be used among 
other things for the following:

   Drying newly completed 

buildings

   Spot heating outdoor 

workspaces or fire-proof 
manufacturing facilities and 
halls

   Continuous or temporary room 

heating

   De-icing machines, vehicles and 

non-combustible warehoused 
goods while adhering to the 
relevant safety distances

CAUTION

Safety devices may be neither 
bypassed nor disabled.

Содержание ELT 9-6

Страница 1: ...d installation instructions This product is suitable only for well insulated rooms or for occasional use Edition EN Z08 Read the instructions prior to performing any task ELT 9 6 REMKO ELT series Elec...

Страница 2: ......

Страница 3: ...list 9 Maintenance protocol 10 Technical data 11 Electrical wiring diagram 11 Contents Carefully read this operating manual prior to commissioning using the units This operating manual is a translati...

Страница 4: ...devices must not be bypassed or disabled The units must not be operated in the vicinity of bathtubs showers swimming pools etc The units must not be operated directly below a wall socket The units mu...

Страница 5: ...ty move the operating switch to the position 2 4 5 kW or 3 9 kW Fan Only the supply air fan operates in this setting Thermostatic regulation and heating operation are not possible in this operating mo...

Страница 6: ...ly clean the units with a dry or moistened cloth Never use direct jets of water such as high pressure cleaners etc Never use abrasive or solvent based cleaners Check the inlet and outlet grille for co...

Страница 7: ...t only be operated by appropriately instructed personnel With non observance of the manufacturer s specifications the respective local legal requirements or after arbitrary alterations to the units th...

Страница 8: ...a Exterior cladding vers INOX 1111101 14 Thermostat assembly 1101066 3 Aftercooler thermostat 1104065 15 Operating switch assembly 1101090 4 Temperature limiter 77 C 1101161 16 Terminal block 6er 1101...

Страница 9: ...Date Signature 11 Date Signature 12 Date Signature 13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Unit...

Страница 10: ...0 Power supply V Hz 400 3 N 50 Max rated current A 13 2 Max power consumption kW 9 7 Auxiliary current consumption at nominal heating power elmax kW 0 105 Auxiliary current consumption at minimum heat...

Страница 11: ...016 Legend K1 Contactor M Motor NK Aftercooler thermostat R1 to R3 Heating resistors for 1st Stage R4 to R6 Heating resistors for 2nd Stage RT Thermostat S Operating switch TB1 Temperature limiter TB2...

Страница 12: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: