![REMKO ELT 2-1 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/remko/elt-2-1/elt-2-1_operating-and-installation-instructions_1438914011.webp)
11
Technical data
We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
230V/1~/50Hz
HR
TB
6
5
4
L1
N
PE
6
5
4
3
2
1
S
1A
2A
3A
4B
5B
6B
I
II
A
B
1
3
4
6
7
9
HW
RT
KL
M
1~
NK
Legend:
AR = Auxiliary relay
HR = Heating resistor
CTS = Connection terminal strip
FM = Fan motor
AT = Aftercooler thermostat
RT = Room thermostat
OS = Operating switch
TL = Temperature limiter
Electrical wiring diagram
1)
at 20 °C intake air temperature
2)
Noise level measurement DIN 45635 - 01 - KL3
FM
AR
HR
CTS
OS
TL
AT
Series
Symbol Unit
ELT 2-1
Nominal heat capacity
P
nom
kW
2,2
Minimum heating power
P
min
kW
2,2
Maximum continuous heating power
P
max,c
kW
2,2
Switchable heating capacity
kW
2,2
Air volume
m
3
/h
250
Air outlet temperature
1)
°C
82
Power supply
V/Hz
230/1~/50
Max. rated current
A
9,5
Max. power consumption
kW
2,25
Auxiliary current consumption at nominal
heating power
el
max
kW
0,2
Auxiliary current consumption at minimum
heating power
el
min
kW
0,2
Auxiliary current consumption in standby
condition
el
SB
kW
0,0
Electrical protection (provided by the customer)
A (slow)
16
Sound pressure level LpA 1m
2)
dB (A)
46
Dimensions:
L/W/H
mm
300/200/315
Type of room temperature control
Room temperature control with
mechanical thermostat
Weight
kg
6,0
Содержание ELT 2-1
Страница 2: ......