REMKO ELT 2-1 Скачать руководство пользователя страница 11

11

Technical data

We reserve the right to modify the dimensions and design as part of the ongoing technical development process.

230V/1~/50Hz

HR

TB

6

5

4

L1

N

PE

6

5

4

3

2

1

S

1A

2A

3A

4B

5B

6B

I

II

A

B

1

3

4

6

7

9

HW

RT

KL

M

1~

NK

Legend:

AR   =  Auxiliary relay
HR  =  Heating resistor
CTS  =  Connection terminal strip
FM  =  Fan motor
AT  =  Aftercooler thermostat
RT  =  Room thermostat
OS  =  Operating switch
TL  =  Temperature limiter

Electrical wiring diagram

1)

 at 20 °C intake air temperature

2)

 Noise level measurement DIN 45635 - 01 - KL3

FM

AR

HR

CTS

OS

TL

AT

Series

Symbol Unit

ELT 2-1

Nominal heat capacity

P

nom

kW

2,2

Minimum heating power

P

min

kW

2,2

Maximum continuous heating power

P

max,c

kW

2,2

Switchable heating capacity 

kW

2,2

Air volume

m

3

/h

250

Air outlet temperature 

1)

 

°C

82

Power supply

V/Hz

230/1~/50

Max. rated current

A

9,5

Max. power consumption

kW

2,25

Auxiliary current consumption at nominal 

heating power

el

max

kW

0,2

Auxiliary current consumption at minimum 

heating power

el

min

kW

0,2

Auxiliary current consumption in standby 

condition

el

SB

kW

0,0

Electrical protection (provided by the customer)

A (slow)

16

Sound pressure level LpA 1m 

2)

dB (A)

46

Dimensions: 

L/W/H

mm

300/200/315

Type of room temperature control

Room temperature control with 

mechanical thermostat

Weight  

kg

6,0

Содержание ELT 2-1

Страница 1: ...d installation instructions This product is suitable only for well insulated rooms or for occasional use Edition EN Q03 Read the instructions prior to performing any task ELT 2 1 REMKO ELT series Elec...

Страница 2: ......

Страница 3: ...nity of the installation location or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Unit description 4 Commissioning 5 Shutdown 6 Care and mai...

Страница 4: ...pools etc The units must not be operated directly below a wall socket The units must not be exposed to direct jets of water e g pressure washers etc Never allow water to enter the units The units must...

Страница 5: ...perates in a fully automatic manner subject to the temperature that is set on the thermostat 1 Set the desired room temperature on the thermostat 2 Move the operating switch to the I Heating position...

Страница 6: ...afety equipment and protective devices on a regular basis Be careful not to damage the thermostat s probe or capillary tube when removing or mounting the rear panel of the unit The unit fan does not s...

Страница 7: ...by appropriately instructed personnel With non observance of the manufacturer s specifications the respective local legal requirements or after arbitrary alterations to the units the manufacturer shal...

Страница 8: ...MKO ELT series We reserve the right to modify the dimensions and design as part of the ongoing technical development process 1 2 6 7 19 17 18 8 5 16 15 9 Exploded view of the unit 12 10 11 3 4 20 15 1...

Страница 9: ...limiter 1101161 5 Inner casing 1103931 6 Heating resistor 1103909 7 Front panel 1101063 8 Floor panel 1103932 9 Fan blade 1103819 10 Drive clutch 1103912 11 Fan motor 1103820 12 Back wall 1103915 13 P...

Страница 10: ...5 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Unit to be maintained only by authorised specialists in accordance with the statutory regulat...

Страница 11: ...eries Symbol Unit ELT 2 1 Nominal heat capacity Pnom kW 2 2 Minimum heating power Pmin kW 2 2 Maximum continuous heating power Pmax c kW 2 2 Switchable heating capacity kW 2 2 Air volume m3 h 250 Air...

Страница 12: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...