8
“MENU / OK” key
(additional functions / con-
firm)
After pressing this key, an additional function can
be activated using the “+” (up arrow), “-” (down
arrow) “L/R SWING” (left arrow) and “U/D SWING”
(right arrow) keys. The selected function flashes in
the display and can be activated or deactivated by
pressing the “OK” key. The following functions are
available:
HEALT
Using this key, the REMKO BioClean function (ioni-
sation) can be activated which contributes to
improving the room air quality.
ECO
(energy saving mode)
After activation of energy saving mode, the con-
troller lowers the compressor frequency to a min-
imum in order to save energy. Energy saving mode
is automatically deactivated after 8 hours and is
only available in cooling mode.
SLEEP
Pressing this key will automatically increase or
decrease the target temperature by 1 °C within an
hour in cooling mode and heating mode respec-
tively. Press this key to maintain the most conven-
ient temperature and save energy.
This function is only available in "Cooling",
"Heating" and "Auto" modes. The unit goes back
into its original state after 10 hours.
SILENCE
(quiet operation)
Activates/deactivates the silent mode.
In silent unit mode, the compressor runs at a lower
frequency, and the indoor unit fan rotates at a
slower speed. This provides particularly quiet unit
operation.
ELE.H
DISPLAY
(display switch-off)
Activating this function switches the display indica-
tors on the indoor unit.
LIGHT
This function is not available.
ELE.H
This function is not available.
I-FEEL
This key can be used to activate/deactivate the I-
FEEL function. In this mode, the room temperature
is measured on the remote control. This sends a
signal to the indoor unit every 3 minutes. If the
remote control does not send a signal to the indoor
unit for 7 minutes, this mode is automatically deac-
tivated.
Anti-F
This function is not available.
iCLEAN
(self-cleaning)
Due to the formation of condensate on the heat
exchanger and the residual moisture that remains,
bacteria can multiply quickly. In regular normal
operation, the heat exchanger is dried by the air
volume flow.
This drying process can also be started manually
with the “Clean” function (for example, if the unit is
not in regular use). In cooling or dehumidification
mode, the self-cleaning function can be activated.
The unit switches off automatically after cleaning
(30 minutes). "CL" appears in the display indicator.
Selection of the self-cleaning function is only pos-
sible in standby mode.
9
"L/R SWING" key
This function is not available.
10
"U/D SWING" key
The oscillation of the horizontal fins can be set
using this key. This function can be switched on
and off by pressing the key.
15