4.
www.remingtonpower.co.nz
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not di-
rectly exposed to water spray, rain, dripping
water, or wind.
WARNING: Risk of burns, fire and
explosion!
NEVER use fuels such as gasoline, benzine,
paint thinners or other oil compounds in this
heater.
NEVER refill the heater’s fuel tank while the
heater is operating or still hot. This heater is
EXTREMELY HOT while in operation.
NEVER block air outlet (front).
NEVER use duct work in front of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
CAUTION: Hot while in operation. Do
not touch. Keep children, animals,
clothing and combustibles away from
heater.
Minimum Clearance From Combustibles
4m from the top, 4m from the sides and 8m
from the front.
ALWAYS locate heater on a stable and level
surface.
If your heater is equipped with a thermostat,
once it is plugged in, it can start at anytime in
accordance with the thermostat setting.
WARNING: Carbon monoxide
poisoning may lead to death!
Carbon monoxide is toxic. Humans can
tolerate only small amounts of carbon mon-
oxide and so precautions should be taken to
provide proper ventilation. Failure to provide
proper ventilation in accordance with the in-
structions in this manual can result in death.
People with breathing problems should con-
sult a physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the flu. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your
heater serviced and check for proper
ventilation. Some people are more affected
by carbon monoxide than others. These
include: pregnant women, those with heart
or lung problems, anemia or those under the
influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: The temporary
heating of adequately ventilated buildings or
structures under construction, alteration or
repair! Provide at least a three square foot
(2,800 sq cm) opening of outside air for
every 100,000 Btu / Hr heater rating. Refer
to “Ventilation” on page 7 for further instruc-
tions.
WARNING: Risk of electric shock!
ALWAYS use only the electrical power (volt-
age and frequency) specified on the model
plate of the heater.
ALWAYS use only three-prong, grounded
outlet and extension cord.