background image

1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989

Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: [email protected]

© 2017 Pinnacle Climate Technologies, Inc.

Содержание REM-200V-LPC-O

Страница 1: ...THE MANUFACTURER DANGER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INS...

Страница 2: ...nd approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other st...

Страница 3: ...NDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Страница 4: ...a from the heater and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect th...

Страница 5: ...e 2 Specifications Model REM 80V LPC O REM 200V LPC O BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Страница 6: ...from inside the heater See Figure 4 2 Remove all packaging protecting the heater during shipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Attach three 3 screws to...

Страница 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on...

Страница 8: ...ition turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connecti...

Страница 9: ...SE to close it REM 200V LPC O 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Страница 10: ...Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from th...

Страница 11: ...time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for ade...

Страница 12: ...R UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2017 Pinnacle Climate Technologies Inc Convection Heater User s Manual Exploded View 11 Figure 8 REM 80V LPC...

Страница 13: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for pr...

Страница 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Отзывы: