•  Do not use if you have tattoos or permanent makeup in the area to be treated.

•  Do not use on dark brown or black spots such as moles, birth marks or freckles.

•  Do not use on an area of recent surgery, deep peel, laser resurfacing, scars or skin that has been 

damaged with burns or scalds.

When not to use/When to avoid using i-LIGHT

•  DO NOT use if you have tanned skin in the intended treatment area, as your skin may be too dark 

and treatment in tanned areas could temporarily cause skin swelling, blisters, or could change the 

colour of your skin. Wait until your tan has faded before treating. 

•  DO NOT use on skin with cosmetics applied, as treating in those areas could temporarily cause 

skin swelling, blisters or could change the colour of your skin. Make sure to thoroughly clean the 

intended treatment area prior to use.

•  DO NOT flash the same treatment spot multiple times during the same session, as this could 

temporarily cause skin swelling, blisters, or could change the colour of your skin.

•  DO NOT treat any area more than every two weeks, as this will not speed up results, but could 

increase likelihood of skin swelling, blistering or changing the colour of your skin.

•  DO NOT use on damaged skin, including open wounds, cold sores, sunburns, or areas where you 

have had a skin peel or other skin resurfacing procedure within the last 6-8 weeks.

•  DO NOT use on irritated skin, including rashes or swollen skin. These conditions can make the skin  

more sensitive. Wait for the affected area to heal before use.

•  DO NOT use if your skin is sensitive to light. In order to determine if you can use i-LIGHT,  

 

perform a test on a small patch of skin and wait 24 hours to determine if there are any adverse  

reactions before treating more broadly.

•  DO NOT use if you are or may be pregnant or are breast-feeding. i-LIGHT has not been tested 

on pregnant women. Hormonal changes are common during pregnancy or breast-feeding and 

could increase skin sensitivity and the risk of skin injury.

•  DO NOT flash against any material other than skin.

•  DO NOT use i-LIGHT for any purpose other than hair removal.

•  DO NOT treat any area where you may someday want your hair to grow back. The results may be 

permanent and irreversible.

•  DO NOT use on the face if you have a history of cold sores; use of IPL or any treatment that irritates 

skin can cause a recurrence of cold sores.

•  If you’ve had professional or clinical or self-administered laser or IPL or electrolysis hair removal  

treatments, wait at least 6 months before using i-LIGHT. If you’ve waxed, plucked or epilated hair 

in the treatment area, wait at least 6 weeks before using i-LIGHT. The device uses the hair under 

your skin to disable your hair at the root, so it is not effective if the hair has been pulled out.

•  Do not use over or near anything artificial such as silicon implants, Implanon contraceptive 

implants, pacemakers, subcutaneous injection ports (insulin dispenser) or piercings.

•  DO NOT use directly over or near Active Implantable Medical Devices such as implantable 

pacemaker, internal defibrillator, or insulin devices. Although no problems associated with the use 

of this device have been reported during studies, it is recommended to observe all active 

implantable medical device warnings regarding the use of electronic devices to prevent any 

failure or interruption of an active implantable device.

•  Wireless communications equipment may affect the i-LIGHT device and should be kept at least 

3.3 m away.

•  Do not use over or near fillings or dental implants.

Содержание iLIGHT IPL8500

Страница 1: ...ENGLISH IPL8500 5 Register online for an EXTRA year guarantee Visit www remington co uk productregister You must register within 28 days of purchase...

Страница 2: ...2 1 2 3 HAIR COLOUR SKIN COLOUR I II III IV V VI 2...

Страница 3: ...3 8 10 11 13 12 6 9 7 4 5...

Страница 4: ...ted surfaces Only use the parts supplied with the appliance Do not twist or kink the cable or wrap it round the appliance Do not plug or unplug the appliance with wet hands This appliance is not inten...

Страница 5: ...hours to determine if there are any adverse reactions before treating more broadly DO NOT use if you are or may be pregnant or are breast feeding i LIGHT has not been tested on pregnant women Hormonal...

Страница 6: ...s surface to target hairs at the root helping to stop their growth Fig 4 The energy in the pulse of light targets dark colouring and best results are seen on darker hair i LIGHT is intended for use on...

Страница 7: ...sp the cap at the positions indicated and firmly pull straight out to release the treatment cap When replacing the cap magnets will assist in aligning the treatment cap into position PREPARING FOR USE...

Страница 8: ...iate power level for each setting based on the skin tone registered This i LIGHT device has 3 different operating modes Power Mode Full Power Sensitive Mode and Express Mode The unit will be in Power...

Страница 9: ...sors are in full contact with the skin 2 Press the flash button to deliver a flash You should expect to see a bright flash of light similar to a camera flash and you should feel a mild sensation of wa...

Страница 10: ...re each flash Stretch Skin for Better Skin Contact the contours of the skin may make it difficult for the skin contact sensors to be fully depressed in certain areas You may find it easier to try and...

Страница 11: ...ys read these instructions fully before using i LIGHT Refer to this troubleshooting guide if you experience any problems with i LIGHT as this section addresses the most common problems you could encou...

Страница 12: ...susceptible to treatment which is why multiple treatments are required for optimal result Another reason for continued growth could be that the area was missed during a treatment Repeat the treatment...

Страница 13: ...nstructions Your statutory rights are not affected To claim an extra 1 year guarantee register your product online within 28 days of purchase Register at www remington co uk productregister Consumable...

Страница 14: ...hester M35 0HS UK www remington co uk Ireland G Tel 142 951 40 Remington Consumer Products Unit B12 Ballymount Corporate Park Ballymount Dublin 12 www ie remington europe com I REGISTER ONLINE Registe...

Страница 15: ...15...

Страница 16: ...8500 T22 7000648 Version 11 18 Remington is a Registered Trade Mark of Spectrum Brands Inc or one of its subsidiaries Spectrum Brands UK Ltd Fir Street Failsworth Manchester M35 0HS www remington co u...

Отзывы: