background image

1

2 YEAR 

WARRANTY

IPL3500AU

Содержание i-LIGHT Compact Control

Страница 1: ...1 2 YEAR WARRANTY IPL3500AU...

Страница 2: ...black skin white grey or very light blonde red hair FOR FACIAL USE Only suitable for female facial use below the cheekbone DO NOT use on or around the eyes eyebrows or eyelashes Doing so can cause se...

Страница 3: ...d chest IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS 1 Use this appliance only for its intended use described in this manual 2 Do not use i...

Страница 4: ...gin check to see if i LIGHT is suitable for you Use the skin and hair chart at the front of this manual page 2 and the integrated skin sensor to determine if this device is right for you For Facial Us...

Страница 5: ...weeks as this will not speed up results but could increase likelihood of skin swelling blistering or changes to the colour of your skin DO NOT use on damaged skin including open wounds cold sores sunb...

Страница 6: ...ur skin to disable your hair at the root so it is not effective if the hair has been pulled out DO NOT use directly over or near Active Implantable Medical Devices such as implantable pacemakers inter...

Страница 7: ...7 i LIGHT COMPACT CONTROL KEY FEATURES PARTS 1 Adapter Socket 2 Energy Level Indicator Lights 5 3 Control Button 4 Ready Light 5 Treatment Window 6 Skin Tone Tester 7 Adapter not shown...

Страница 8: ...take 18 24 months During this time multiple treatment sessions are required to achieve permanent hair reduction A typical hair reduction plan during a full hair growth cycle includes Treatments 1 6 Pl...

Страница 9: ...ned on the energy level is set to level 1 automatically Only one energy level indicator light will be on To change the energy level press the control button repeatedly to increase the energy level fro...

Страница 10: ...igmentation The built in skin tone tester detects the colour of your skin automatically The skin tone tester checks your skin colour at the start of and occasionally during each treatment If your skin...

Страница 11: ...ng at increased energy levels If you do not experience any adverse effects within 24 hours you can start the full treatment at that energy level Use a lower energy level if you experience any discomfo...

Страница 12: ...the control button an extended press Remember the last energy level setting you used because it will not be restored when you turn the device on again 2 Remove the adapter from the electrical outlet C...

Страница 13: ...e the adapter is properly connected to the device and that it is plugged into an electrical outlet on the wall There is no light pulse when the device touches my skin Check that the device is connecte...

Страница 14: ...like the hair is still growing but it is actually being pushed out Hair grows in a cycle of 3 different phases which lasts 18 24 months Only hairs in the active growth phase are susceptible to treatme...

Страница 15: ...ring within the guarantee period will be corrected by replacement or repair at our discretion provided the product is used and maintained in accordance with the instructions Defects from repair by an...

Страница 16: ...ilure does not amount to a major failure 2 The benefits provided by this Warranty are in addition to all other rights and remedies in respect of the Goods which the consumer has under either the Austr...

Страница 17: ...Supplier the date and place of purchase the product name or other product serial number and ii this warranty 9 This warranty is immediately void if a Any serial number or appliance plate is removed o...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...ck Offer Australia New Zealand Only If within 90 days you are not fully satisfied with your Remington i LIGHT Compact Control please call your local Remington Customer Service Centre Australia 1800 62...

Отзывы:

Похожие инструкции для i-LIGHT Compact Control