NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2014, Pinnacle Products International, Inc.
Dual Fusion Forced Air Heater User’s Manual
Maintenance
Service (Continued):
)$1%/$'(6
Blades should be cleaned at least once per
heating season, depending on conditions.
Remove all accumulated dust and dirt with a
damp cloth, taking care not to bend any of the
fan blades. Be sure the blades are dry before
re-starting the heater. For fan assembly removal
see Figure 7.
)8(/),/7(5
The fuel filter should be cleaned at least twice
per heating season. Clean the filter by rinsing
it in clean 1-K Kerosene. Contaminated fuel
could make cleaning the fuel filter necessary
immediately.
127(7RUHPRYHWKHILOWHUIURPPRGHOVWXUQ
ILOWHUFRXQWHUFORFNZLVH6HH)LJXUH
63$5.3/8*
Clean and re-gap every 600 hours of operation, or
replace as needed. After removing the spark plug,
clean the terminals with a wire brush. Re-gap the
WHUPLQDOVWR´PP6HH)LJXUH
3+272&(//
The photocell should be cleaned using a cotton
swab dipped in alcohol or water at least once
per heating season, or more depending on
conditions. See Figure 10.
Figure 7
Fan Blade
Motor Shaft
Set Screw
Figure 8
Fuel Filter
Fuel Line
Figure 9
Ignitor Wire
Spark Plug
*DSPP
Burner Head
X
X
Figure 10
Photocell
Photocell lens
Photocell Wire
9
Motor
Siroco Fan
Fuel Tank