4
The parameters
p1
to
p8
are changed in the
same way as
p1
. After step 2, use the
[+]
key to
move to the required parameter.
4
The parameters
p1
(the maximum heating water
temperature) and
p2
(the maximum drinking water
temperature) can also be modified using the quick
selection menu.
5.7.3.
Modification of the installer-level
parameters
Parameters
p17
to
df
must only be modified by a qualified
professional. To prevent unwanted settings, some parameter settings
can only be changed after the special access code
0012
is
entered.
If the boiler has been modified, for example:
4
G20 (Gas H) or G31 (Propane)
4
high pressure systems
4
WTW coupling
4
CLV overpressure (combusted gas discharge
systems)
It is necessary to mention on the sticker provided: This
boiler has been set for.... This sticker must be affixed to the
top of the boiler next to the identification plate.
CAUTION
Modification of the factory settings may be detrimental to
the functioning of the appliance.
1. Press the two keys
f
simultaneously and then key
[+]
until the
symbol
?
flashes on the menu bar.
2. Select the fitter menu using the
key.
c0de
appears on the
display.
3. Use keys
[-]
or
[+]
to input the installer code
0012
.
4. Confirm using key
S
.
p[1
is displayed with
1
flashing.
5. Press the
S
key a second time. The value
80
°C appears and
flashes (for example).
6. Change the value by pressing the
[-]
or
[+]
key. In this example
using key
[-]
to
60
°C.
7. Confirm the value with the
S
key:
p[1
is displayed with
1
flashing.
8. If necessary, set other parameters by selecting them using the
[-]
or
[+]
keys.
9. Press the
>
key 2 times to return to the current operating
mode.
The boiler also returns to operating status if no keys are
pressed for 3 minutes.