Remeha Avanta Exclusive

126582-160412

4.  Changing boiler settings

4  CHANGING BOILER SETTINGS

2x

2x

2x

2x

1.  Changing P1 setting: flow temperature of water in central heating system

R000188-A

Reduce the flow temperature as follows:
•  

Press the 

f

-key

 

until the 

W

 symbol flashes in the menu bar.

•  

Select the users menu using the 

S

-key. 

p[1

 

is displayed with 

1

 flashing.

•  

Press the 

S

-key a second time. The value 

75

°C appears and flashes.

•  

Change the value by pressing the 

[+] 

or 

[-] 

key. In this example, use the 

[-]

-key to 

change the value to 

70

°C.

•  

Confirm the value with the 

S

-key. 

p[1

 

is displayed with 

1

 flashing.

•  

Press 2 times on the 

>

-key

 

to return to the current operating mode.

R000189-A

Increase the domestic hot water temperature as follows:
•  

Press the 

f

-key

 

until the 

W

 symbol flashes in the menu bar.

•  

Select the users menu using the 

S

-key. 

p[1

 

is displayed with 

1

 flashing.

•  

Press the 

[+]

-key. 

p["

 is displayed with 

"

 flashing.

•  

Press the 

S

-key a second time. The value 

55

°C appears and flashes.

•  

Change the value by pressing the 

[+] 

or 

[-] 

key. In this example, use the 

[+]

-key 

to change the value to 

65

°C.

•  

Confirm the value with the 

S

-key. 

p[2

 

is displayed with 

2

 flashing.

•  

Press 2 times on the 

>

-key

 

to return to the current operating mode.

3.   Changing P3 setting: boiler regulation (domestic hot water and central 

heating mode)

0

 = CH 

off

 / DHW 

off

 

1

 = CH 

on

 / DHW 

on

 (factory setting)

2

 = CH 

on

 / DHW 

off 

3

 = CH 

off

 / DHW 

on

Change the boiler regulation as follows:

R000190-A

2x

2x

•  

Press the 

f

-key

 

until the 

W

 symbol flashes in the menu bar.

•  

Select the users menu using the 

S

-key. 

p[1

 

is displayed with 

1

 flashing.

•  

Press the 

[+]

-key several times. 

p[3

 is displayed with 

3

 flashing.

•  

Press the 

S

-key a second time. The setting 

1

 appears and flashes.

•  

Change the setting by pressing the 

[+] 

or 

[-] 

key. In this example, use the 

[+]

-key 

to change the setting to 

2

 (CH 

on

 / DHW 

off

).

•  

Confirm the value with the 

S

-key. 

p[3

 

is displayed with 

3

 flashing.

•  

Press 2 times on the 

>

-key

 

to return to the current operating mode.

Remeha is a licensed member of the Benchmark Scheme which aims to improve the standards 

of installation and commissioning of domestic heating and hot water systems in the UK and to 

encourage regular servicing to optimise safety, efficiency and performance.

Benchmark is managed and promoted by the Heating and Hotwater Industry Council.

For more information visit www.centralheating.co.uk

2.  Changing P2 setting: domestic hot water temperature

Содержание Avanta Exclusive 28C

Страница 1: ...wall hung boilers EN United Kingdom User s Operation Instructions Important Warranty Information Avanta Exclusive 28C 35C 39C Please keep these instructions in a safe place If you move house please h...

Страница 2: ...alled commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checkli...

Страница 3: ...those present and leave the building together Call your installer once you are outside the building Installation location for the boiler Do not store or use any flammable materials aggressive substan...

Страница 4: ...nd call your installer Check yellow gas valve bottom boiler gas valve must be in line with gas supply pipe if necessary open gas valve Press J key Wait for recovery display shows 0 boiler functions pr...

Страница 5: ...Set the room thermostat to as low a temperature as possible 3 Switch off the boiler electrical power supply 5 Open the filling loop valve 6 Close the filling loop valve when the manometer indicates t...

Страница 6: ...with the S key p 2 is displayed with 2 flashing Press 2 times on the key to return to the current operating mode 3 Changing P3 setting boiler regulation domestic hot water and central heating mode 0 C...

Страница 7: ...h 1 flashing Press the key several times p 4 is displayed with 4 flashing Press the S key a second time The setting 2 appears and flashes Change the setting by pressing the or key In this example use...

Страница 8: ...0 Contact Information Sales Office 0844 8711544 After Sales Service 0844 879 7690 Literature 0844 879 7690 Training 0844 879 7690 Technical Helpline 0118 974 3070 Spares Sales Office 0844 871 1540 230...

Страница 9: ...appear showing all segments of the display fK xx software version pK xx parameter version A venting cycle of 3 minutes now follows the version numbers will be displayed alternately Next the following...

Страница 10: ...an engineer visit or for any general advise that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When...

Страница 11: ...ilding Regulations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certifi c...