CELL INSTALLATION
3.1
The electrolytic cell housing must be plumbed into the return line after the filter. Please
refer to the installation diagram, Fig.1, below for the preferred method. The cell housing has
allocations for either 40mm PVC pipe or 50mm PVC pipe with the use of the supplied PVC
reducing bushes.
3.2
If a heater is plumbed into the system, then the cell housing must be installed after the heater
in the return line to protect the elements or heat exchanger. If a solar heating system is fitted,
then the cell housing should be installed after the return line coming back from the roof if it
rejoins the main swimming pool return line.
CELL HOUSING
POWER OUTLET
TO POOL
RETURN
FROM POOL/
SKIMMER
BACKWASH LINE
POWER PACK CONTROLLER
Self Cleaning
Mineral / Salt Chlorinator
CELL HOUSING
CELL LOCATING LUG RECESS
WATER PROBE*
CELL LOCATING LUG
O-RING SEAL
CELL
CAP
TOP
Fig. 1
Fig. 2
Please note the installation position of the electrolytic cell for water probe positioning. Water probe faces top.