background image

7

ENGLIS

CH

APPlIcATIon In AccoRDAnce WITh ReGUlATIonS

This device is an active loudspeaker which amplifies and plays low level audio signals. 

This product is authorised for connection to 220 V, 50 Hz AC and is designed exclusively for indoor application.

 If the device is used for any other purposes than those described in the operation manual, damage can be caused to the product, leading to 

the exclusion of warranty rights. Moreover, any other application that does not comply with the specified purpose harbours risks such as short 
circuit, fire, electric shock, etc.

The serial number determined by the manufacturer must never be removed to uphold the warranty rights.

MAInTenAnce

 Check the technical safety of the device regularly for damage to the mains line or the casing, as well as for wearout of wear parts such as 
rotary and sliding switches.

 If it is to be assumed that a safe operation is no longer feasible then the device must be disconnected and secured against accidental use. 
Always disconnect the mains plug from the outlet!

 It must be assumed that a safe operation is no longer feasible if the device bears visible defects, if the device no longer functions, following 
longer storage under unfavourable conditions or after major transport stress.

conTRol eleMenTS

Designation

1. 

ON/OFF Switch

2.  Signal Input (RCA)
3.  Signal Output Subwoofer (3.5 mm Jack)
4.  Volume Control 
5.  Bass Control 
6.  Treble Control 
7.  Screw-In Clamp for 2nd Speaker
8.  Connector for Mains Cord
9.  Fuse (1A)

1.

2.

3.

4.

5.

6.

7.

8.

9.

Содержание ADM-4

Страница 1: ... les personnes chargées de l installation de la mise en service de l utilisation de l entretien et la maintenance de cet appareil doivent possé der les qualifications nécessaires et respecter les instructions de ce mode d emploi Ce produit est conforme aux directives européennes et nationales la conformité a été certifiée et les déclarations et documents sont en possession du fabricant WARNUNG Um ...

Страница 2: ...harakteristik und Nennstromstärke ausgetauscht werden Stecken Sie das Stromkabel nur in geeignete Schukosteckdosen ein Als Spannungsquelle darf dabei nur eine ordnungsgemäße Netzsteckdose des öffentlichen Versorgungsnetzes verwendet werden Trennen Sie das Gerät bei Nichtbenutzung und vor jeder Reinigung vom Netz Fassen Sie dazu den Netzstecker an der Grifffläche an und ziehen Sie niemals an der Ne...

Страница 3: ...e regelmäßig die technische Sicherheit des Gerätes auf Beschädigungen des Netzkabels oder des Gehäuses sowie auf die Abnutzung von Verschleißteilen wie Dreh und Schiebereglern Wenn anzunehmen ist dass ein gefahrloser Betrieb nicht mehr möglich ist so ist das Gerät außer Betrieb zu setzen und gegen unbeabsich tigten Betrieb zu sichern Netzstecker aus der Steckdose ziehen Es ist anzunehmen dass ein ...

Страница 4: ...diokonsole in Kopfhöhe aufgestellt Dazu sollten die Monitore und die Position des Hörers in einem gleichschenkeligen Dreieck aufgebaut werden Bei dieser Installation sind die Monitore in einem gleichmäßigen Winkel von 60 zur Hörposition aufgebaut Mittelfeld Installation Diese Installation ist vom Prinzip her ähnlich wie die Nahfeld Installation Diese Variante wird normalerweise bei größeren Monito...

Страница 5: ...benötigt eine Erhöhung der hohen Frequenzen Umgekehrt ist eine Absenkung der hohen Frequenzen in wiederhallenden Räumen nötig Positioniert man die Monitore nahe einer Wand oder Raumecke so werden die tiefen Frequenzen verstärkt Platziert man die Monitore in einer größeren Entfernung so werden die tiefen Frequenzen verringert Technische Daten Reloop ADM 4 RMS Leistung 2 x 16W Bauart Aktives 2 Wege ...

Страница 6: ...current rating Connect the power cable exclusively to appropriate shock proof outlets The only supply point to be used is a supply outlet in accordance with specifications of the public supply network Disconnect the device from the supply outlet when not in use and before cleaning Be sure to hold the mains plug by the body Never pull the mains cord Position the device on a horizontal and stable lo...

Страница 7: ...the warranty rights Maintenance Check the technical safety of the device regularly for damage to the mains line or the casing as well as for wearout of wear parts such as rotary and sliding switches If it is to be assumed that a safe operation is no longer feasible then the device must be disconnected and secured against accidental use Always disconnect the mains plug from the outlet It must be as...

Страница 8: ...placed on the studio console face level For this purpose the positioning of the monitors and the listener should be arranged in an equilateral triangle In this installation the monitors are placed at a 60 angle to the listening position Mid Field Installation This installation is more or less the same as the close field installation This variant is usually used if the monitors are too large or hea...

Страница 9: ...requencies whereas a reverberant room requires a reduction of the high frequencies If the monitors are positioned near a wall or corner the low frequencies will be raised If the monitors are positioned in a bigger distance the low frequencies will be lowered Technical information Reloop Wave 4 RMS power 2 x 16W Type Active 2 way system S N Ratio 75dB Speaker 10 16 cm 4 bass 2 54 cm 1 tweeter Frequ...

Страница 10: ...istiques de déclenchement et d un am pérage identique Assurez vous que le produit soit exclusivement branché sur une tension alternative de 220 V 50 Hz Insérez uniquement le cordon d alimentation dans des prises électriques de sécurité La source de tension utilisée doit uniquement être une prise électrique en ordre du réseau d alimentation publique Débranchez l appareil lorsque vous ne l utilisez ...

Страница 11: ... état de l appareil boîtier cordon et l usure éventuelle des molettes et curseurs Si vous supposez que l appareil ne peut plus être utilisé en toute sécurité mettez l appareil hors service et assurez le contre toute réutilisa tion involontaire Débranchez la fiche électrique de la prise de courant La sécurité d emploi est susceptible d être affectée lorsque l appareil est visiblement endommagé ne f...

Страница 12: ...console de studio à hauteur de tête Les moniteurs et la position de l écouteur doivent alors former un triangle équilatéral Dans le cas de cette installation les moniteurs sont positionnés à des angles égaux de 60 par rapport à la position d écoute Installation à mi distance Cette installation est en principe similaire à celle de proximité Cette variante est normalement choisie pour des moniteurs ...

Страница 13: ...s aigus Au contraire dans une pièce qui résonne il convient d abaisser les aigus Si les moniteurs sont installés près d un mur ou d un angle les graves sont renforcés L installation lointaine des moniteurs diminue les graves Caractéristiques Reloop ADM 4 Puissance RMS 2 x 16W Type de construction système actif 2 voies Rapport signal bruit 75 dB Enceinte 10 16 cm q 4 graves 2 54 cm 1 aigus Réponse ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...16 ...

Отзывы: