Slave ID –
Total 16 monitors can be linked in cascade. User can assign an ID
number to a monitor by using the OSD menu.
Thermal –
The monitor has two internal thermal sensors which are linked to
two fans for internal temperature control.
Temperature –
The temperatures detected by the thermal sensors will be
shown on Fan1 and Fan2.
FanOn/FanOff –
User can preset a temperature for the on/off of Fan1 and
Fan2. For example, if the temperature is set a 24
℃
, the fan will be
turned on at 25
℃
and turned off at 23
℃
.
Timer –
The monitor has a built-in timer which can last for about two weeks
without being connected to the power source.
Photo –
The monitor is with three built in photo sensors to detect the level of ambient
light and the backlight.
Foto1, foto2 –
These two sensors are located at lower left and lower right
corners for ambient light detection. The light level will be indicated on a
scale from 0 to 63.
Foto3 –
This sensor is located near the backlight lamp for detecting the
backlight level.
DIMMER control –
There are three options for the dimmer control.
Manual –
To manually adjust the backlight level.
Auto1 –
The monitor will adjust the backlight automatically in accordance with
the feed back from the light sensors.
Auto2 –
It works the same way as Auto1 but in a faster speed of adjustment.
19