APPLYING THE ARM CUFF

13

4. Apply the cuff to your left upper arm so the blue arrow is centered 

on the inside of your arm and aligned with your middle finger. 
The air tube runs down the inside of your arm. The bottom of the 
cuff should be approximately 1/2" above your elbow.

5. Wrap the cuff firmly in place around your arm using the closure strip.

APPLYING THE CUFF ON THE RIGHT ARM

When taking a measurement using the right arm use this instruction 
for Step 4.

NOTE:

Be careful not to rest your arm on the air tube. 

This will restrict the flow of air to the cuff. 

1/2 inch (1 - 2 cm)

Air Tube

Marker

412CRELN2 IM.tif  1/23/06  9:23 AM  Page 13

Содержание HEM-412CREL

Страница 1: ...Manual Inflation Blood Pressure Monitor Model HEM 412CREL INSTRUCTION MANUAL ESPA OL ENGLISH...

Страница 2: ...lay 7 Battery Installation 8 Setting the Date and Time 9 Applying the Arm Cuff 12 Taking a Measurement 14 Using the Memory Function Averaging Function 16 Measurement Values 16 Care and Maintenance Car...

Страница 3: ...od pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a ste...

Страница 4: ...pressure Follow the instructions of your healthcare provider Operate the unit only as intended Do not use for any other purpose The unit is intended for use in measuring blood pressure and pulse rate...

Страница 5: ...m on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Keep a record of your blood pressure and pulse readings for your physician A si...

Страница 6: ...UNIT Cuff Air Plug Main Unit Battery Compartment ON OFF Button MEMORY Button Settings Button Display Components Air Tube Operating Instructions Bulb Air Plug Air Release Button Air Tube Arm Cuff Infl...

Страница 7: ...Diastolic Blood Pressure Systolic Blood Pressure Memory Symbol Pulse Display Date Time Display Battery Low Symbol Average Value Symbol Heartbeat Symbol Deflation Symbol UNIT DISPLAY Reinflation Symbo...

Страница 8: ...icated 3 Replace the battery cover BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen remove all the batteries Replace with four new batteries at th...

Страница 9: ...t values The monitor also calculates an average reading based on the three most recent measurements taken within 10 minutes of the last reading NOTE If only two readings are stored in the memory for t...

Страница 10: ...ear The month flashes on the display NOTE Press and hold the MEMORY button to advance the date and time values faster 3 SETTING THE MONTH Press the MEMORY button to advance by increments of one month...

Страница 11: ...one hour Press the Date Time Setting button to set the current hour The minutes flash on the display 6 SETTING THE MINUTE Press the MEMORY button to advance by increments of one minute Press the Date...

Страница 12: ...the air tube of the arm cuff and the inflation bulb to their air jacks 2 Remove tight fitting clothing from your upper arm 3 Sit in a chair with your feet flat on the floor Place your arm on a table s...

Страница 13: ...your arm The bottom of the cuff should be approximately 1 2 above your elbow 5 Wrap the cuff firmly in place around your arm using the closure strip APPLYING THE CUFF ON THE RIGHT ARM When taking a me...

Страница 14: ...a measurement 2 Begin inflating the cuff by rapidly squeezing the inflation bulb until you have reached approximately 30 40 mmHg higher than your normal systolic reading If your normal systolic blood...

Страница 15: ...bulb to re inflate the arm cuff 5 When the Deflation Symbol appears on the display press the Air Release Button to release the air left in the cuff 6 The measurement is complete the Heart Symbol stop...

Страница 16: ...average reading based on the values of the three most recent measurements taken NOTE If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If...

Страница 17: ...urement values will be displayed NOTES Press the button repeatedly to display the next values Press and hold the button to display the values faster 2 Press the ON OFF button to turn the power off TO...

Страница 18: ...the cuff Never immerse the monitor or any components in water Store the monitor in a safe and dry location Do not subject the monitor to extreme hot or cold temperatures humidity and direct sunlight A...

Страница 19: ...f over inflated TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power No display appears on the unit Replace worn batteries Check the battery installation for proper placement of the battery pola...

Страница 20: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit differen...

Страница 21: ...ation for warranty service is available on our website at www omronhealthcare com Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific pro...

Страница 22: ...es Battery Life Approx 600 uses when used twice a day with new AAA standard batteries Operating Temperature 50 F to 104 F 10 C to 40 C 30 to 85 RH Humidity Storage Temperature 4 F to 140 F 20 C to 60...

Страница 23: ...NOTES...

Страница 24: ...0 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Manufactured by Omron Made in China Copyright c 2005 Omron Healthcare Inc ReliOn is a registered trademark used under license by Omr...

Отзывы: