PROBLEM
POSSIBLE CAUSES
Uneven heating, sides burning
A. Burner valves improperly adjusted
B. Fluctuating gas pressure
C. Improperly adjusted burner
Too much top heat
A. Burner valves adjusted too high
B. Faulty ventilation
C. Overrated gas pressure
D. Improperly adjusted burner
Uneven heat side to side
A. Burner valves improperly adjusted
B. Appliance is not level side to side
C. Improperly adjusted burner
Pilot outage
A. Pilot flame is set too low. Adjust pilot to allow for gas flow.
B. Obstruction in pilot orifice
C. Low gas pressure.
Yellow burner flames
A. Open burner shutters until flames are blue
Lifting burner flames
A. Close burner shutters until flames touch burner
Fluctuating gas pressure
A. Check for clogged vent on regulator
PRODUCT SPECIFICATION SHEET
MODEL
STYLE
MANUAL
GAS TYPE
MANIFOLD
PRESSURE
TOTAL B.T.U.
PER HOUR
REL-GCB-24
4 Burners w/
individual control
Natural Gas
Propane Gas
4.0" W.C.
10.0" W.C.
80,000
REL-GCB-36
6 Burners w/
individual control
Natural Gas
Propane Gas
4.0" W.C.
10.0" W.C.
120,000
REL-GCB-48
8 Burners w/
individual control
Natural Gas
Propane Gas
4.0" W.C.
10.0" W.C.
160,000
REL-GCB-60
10 Burners w/
individual control
Natural Gas
Propane Gas
4.0" W.C.
10.0" W.C.
200,000