Reliance SG777 Скачать руководство пользователя страница 4

 

 

 

 

 
 

16633 Foltz Parkway 

 Strongsville, OH  44149 USA   Telephone: +1 (440) 572-1500   

  Fax: +1 (440) 238-8828 

www.clark-reliance.com  

  [email protected]

 

 

 

When mounting Steel Water Gage Valves, make sure they are mounted in exact alignment, especially when tubular glass 
is used during Boil-out procedures. Any angular or offset misalignment of the valves will strain the tubular glass and may 
cause early failure. When installing the armored type gage glass, any misalignment could cause a leak from the flanged 
connection that may result in damage to the valve or gage glass.

  

When mounting the boil-out tubular glass and valves in 

vertical mounting applications, the overall length of the gage should be 1 ¼” less than the valve centers.  
 
When mounting water gage valves and a gage glass directly to the vessel, the valve centers must be secured to prevent 
movement which could result in leakage around the gage glass flanged connection. Use of a Tie Bar with U-bolts, water 
column, or Standpipe to keep the water gage valve centers from expanding is recommended. 

 

Installing the valves: 

The valve set contains two valves: an upper and a lower. The lower valve has a ½” FSW/FNPT drain connection and 
must be installed on the lower connection to guarantee proper operation of the valves and gage glass. 
 
Reliance SG777 Series steel water gage valves typically are furnished with three types of vessel connections: 

1)  1 ½” Female Socket Weld 
2)  ¾” Male NPT 
3)  ¾” Male Socket Weld 
4)  Other connections are available on request 
 

  If furnished with male NPT connections, coat the threads with a pipe joint compound such as TYTE-UNYTE® Thread 

Sealing Compound or equal. Assemble the upper and lower valves on to the vessel connections making sure there is 
no angular or offset misalignment of the valves. Note that the valves should be seal welded to the connections. This is 
normally recommended for installations that operate over 900 PSIG. Welding is to be done by ASME Section IX 
qualified welders and with approved welding procedures and Section II approved welding materials. 

 

  If the valves are furnished with female socket weld connections, care must be taken to orient the valves so there is no 

angular or offset misalignment. Welding is to be done by ASME Section IX qualified welders and with approved 
welding procedures and Section II approved welding materials. 

 

  If the valves are furnished with male socket weld connections, care must be taken to orient the valves so there is no 

angular or offset misalignment. Welding is to be done by ASME Section IX qualified welders and with approved 
welding procedures and Section II approved welding materials. 

 

 
Attaching  the Gage Glass  
 
Lubricate the bolting with high temperature nickel based lubricant (Molycote “G” or equal). When using the standard ½”-
2500# RTJ flanges, place the R-13 Oval Ring between the upper and lower flanges. Using a calibrated torque wrench, 
torque the nuts to 85 ft-lbs in the proper sequence. 

                                                                       

 

 
 

Содержание SG777

Страница 1: ...sville OH 44149 USA Telephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com Reliance SG777 Series Steel Water Gage Valves Installation Operation Maintenance Instructions R500 SG777 10 16 2016 ...

Страница 2: ...Note Design variations in Steel Water Gage Valves necessitate typical illustrations but basic elements are similar in function and appearance ...

Страница 3: ...ith each shipment Report any discrepancies to Clark Reliance immediately Have the Clark Reliance order number and shipping waybill available at the time of your call Handling Your Clark Reliance shipment has been carefully packed However the shipment may include spare parts temporary water gages and valves for Boil out purposes maintenance instructions and engineering drawings Upon receipt of the ...

Страница 4: ...e types of vessel connections 1 1 Female Socket Weld 2 Male NPT 3 Male Socket Weld 4 Other connections are available on request If furnished with male NPT connections coat the threads with a pipe joint compound such as TYTE UNYTE Thread Sealing Compound or equal Assemble the upper and lower valves on to the vessel connections making sure there is no angular or offset misalignment of the valves Not...

Страница 5: ...r purged of any water Failure to do this may result in a sudden release of pressure and fluids which could cause physical injury to personnel Repacking the valves 1 Remove stem bushing locking set screw loosen with a 5 32 hex wrench to clear bushing threads Figure 2 Figure 2 2 Remove stem stem bushing packing yoke and all old packing material Inspect packing chambers for pitting or steam cut Polis...

Страница 6: ...check for leakage and re tighten cap screws if necessary shortly after boiler is returned to service FIELD INSTALLATION OF LIVE LOADING KIT RK 34 FOR SG777 SERIES WATER GAGE VALVES The RK 34 Live Loading kit is available to improve the performance and service live of Clark Reliance Steel Water Gage Valves that are already installed in the field Live loading offers a more leak free valve resists da...

Страница 7: ...16633 Foltz Parkway Strongsville OH 44149 USA Telephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com REPLACEMENT PARTS FOR SG777 SERIES VALVES ...

Страница 8: ...16633 Foltz Parkway Strongsville OH 44149 USA Telephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com ...