Model G Conventional Sprinkler

SIN R1077

 

Technical Specifications

 Style:

 Upright or Pendent

 Threads:

 3/4” BPST

 Nominal K-Factor:

 8.2 (118.2 metric)

 Max. Working Pressure:

 175 psi (12 bar)

 

Material Specifications

Thermal Sensor: 

Solder Capsule

Sprinkler Frame: 

Leaded Red Brass Alloy

Cap: 

Brass Alloy with PTFE

Load Screw: 

Brass CDA Alloy

Deflector: 

Brass CDA Alloy

 

 

Sprinkler Finishes 

(See Table B)

 

Sensitivity

Standard Response

Temperature Ratings

135°F (57°C)
165°F (74°C)
212°F (100°C)
286°F (141°C)

Sprinkler Wrenches

 Model W2

Listings and Approvals

LPCB
Pleniere Assemblee
CE (1438-CPR-0052)

Model G (3/4”) Conventional Sprinkler Components and Dimensions

Figure 3

Bulletin 079
May 2021

Page 4 of 6

www.reliablesprinkler.com

Содержание G Series

Страница 1: ...t the ceiling and the remainder downward to the floor and may be used in either the upright or pendent position Reliable Model G Conventional Sprinklers are standard response fire sprinklers utilizing a solder capsule strut and lever thermal element These sprinklers are available in 4 10 59 1 metric 5 62 81 0 metric and 8 2 118 2 metric K factor When used in the pendent position sprinklers may be ...

Страница 2: ...nkler Frame Leaded Red Brass Alloy Cap Brass Alloy with PTFE Load Screw Brass CDA Alloy Deflector Brass CDA Alloy Sprinkler Finishes See Table B Sensitivity Standard Response Temperature Ratings 135 F 57 C 165 F 74 C 212 F 100 C 286 F 141 C Sprinkler Wrench Model W2 Listings and Approvals Pleniere Assemblee Model G 3 8 Conventional Sprinkler Components and Dimensions Figure 1 Bulletin 079 May 2021...

Страница 3: ... Leaded Red Brass Alloy Cap Brass Alloy with PTFE Load Screw Brass CDA Alloy Deflector Brass CDA Alloy Sprinkler Finishes See Table B Sensitivity Quick Response Temperature Ratings 135 F 57 C 165 F 74 C 212 F 100 C 286 F 141 C Sprinkler Wrenches Model W2 Listings and Approvals LPCB Pleniere Assemblee CE 1438 CPR 0052 Model G 1 2 Conventional Sprinkler Components and Dimensions Figure 2 Bulletin 07...

Страница 4: ...Leaded Red Brass Alloy Cap Brass Alloy with PTFE Load Screw Brass CDA Alloy Deflector Brass CDA Alloy Sprinkler Finishes See Table B Sensitivity Standard Response Temperature Ratings 135 F 57 C 165 F 74 C 212 F 100 C 286 F 141 C Sprinkler Wrenches Model W2 Listings and Approvals LPCB Pleniere Assemblee CE 1438 CPR 0052 Model G 3 4 Conventional Sprinkler Components and Dimensions Figure 3 Bulletin ...

Страница 5: ...ce any sprinkler which has been painted other than factory applied A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers Failure to properly maintain sprinklers may result in inadvertent operation or non operation during a fire event Standard Finishes Special Application Finishes Bronze Bright Brass 3 Chrome Plated Black Plated White Polyeste...

Отзывы: