4.After set communication address value, press [OK] key to confirm, the
communication address setting is successful if heard once
bee
hoot and the
interface is turned to standby interface, the communication address setting is
failed if heard twice
Bee
hoots, re-press [OK] key to confirm or return to the
st
1 step to reset.
COMMON PHENOMENON DISPOSAL
PRODUCT SPECIFICATION
Model
ZH05C
Name
Air massage mattress with lifting function
Rated Voltage
110-120V~ 60Hz
220-240V~ 50Hz/60Hz
Rated Power Input
85W
Safety Structure
Phenomenon
The product doesn't
work when power on
Machine suddenly
stop working
Potential cause
Unwell contact of both
lifting mechanism plugs
Unwell contact between
plug and socket
Power on or not
Disposal method
Inspect the plug of lifting
mechanism and driven box to
make them contact
Inspect power of socket to
ensure plug and socket
contact well
Inspect and recover
When pressing the
lifting key, no up and
down changes for
the bed frame
Whether the power cut
and air release switch are
off
Rotate the power cut and air
release switch to keep them
off
3
Set communication address value through Navi and Digital Keys, totally 4
address values, setting range of each address value is among 0 to 255. (Schematic
diagram of remote controller digital keys)
Setting method: the
*
sign in the communication address setting interface
represents the current data bits to be set, change the data bits through Navi Key,
and set the value of current data bits through digital key.
0
1
2
3
4
5
6
7
8
9
OK
WAIST
STRETCH
AUTO
2. Into the address setting interface
With the standby state of the handheld remote controller, press the
Auto
button and the
AUTO
button at the same time, then release, in to the
address setting interface (the two buttons pressed at the same time)
Address code setting
Nation code
Customer code
Serial No.
Batch Number
SET REMOTE COMMUNICATION ADDRESS CODE