INSTALLTION FOR
MINIATURE THERMOSTATIC VALVE
Rev. 8/19
P a g e
|
2
4.
Use the
Plastic Mudguard (1)
(part of the package) to position the
Valve (2)
in the wall. This is done
by checking the markings on the mudguard for the minimum/maximum settings which is 2 3/8” to 2
7/8
” from the center of the valve inlets to the finished wall.
Diagram 2: Plastic Mudguard
5.
Connect the outlet pipe(s). Install tile stops/volume controls between the thermostatic valve and
each device to be operated.
NOTE:
Port marked V will output about 6.5 gpm and port marked D will put out about 4.5 gpm at 45 psi.
NOTE:
Shared ports are only between ports marked D1 and D2 on the SS-TH80 valve.
Trim Installation
(see Diagram 4)
1.
Screw
Temperature Control Dome (1)
and
Volume Control Dome (9)
onto valve.
NOTE:
The
Temperature Control Dome (1)
has a larger opening than the
Volume Control Dome (9).
2.
Slide the
Thermostatic Face Plate (3)
onto the valve by sliding over the
Temperature Control Dome
(1)
and
Volume Control Dome (9)
and hold in place.
3.
Screw
Lock Rings (4)
into
Dome Sleeves (2)
.
4.
Lock the
Thermostatic Face Plate (3)
securely against the wall by screwing
Dome Sleeves (2)
with
Lock Rings (4)
onto
Temperature Control Dome (1)
and
Volume Control Dome (9)
.
5.
Ensure
Temperature Limit Stop Ring (5)
is installed with
red dot at 12 o’clock position
6.
Install
Temperature Control Post (6)
onto valve
with push button at 12 o’clock position
and install
Temperature Control Handle (8)
onto
Temperature Control Post (6)
.
Note:
Some heavier lever handles come with friction washers to prevent rotation due to gravity. The
thicker of these washers is for use with this valve when needed (see Diagram 3).
7.
Install
Volume Control Post (10)
onto valve and install
Volume Control Handle (12)
onto
Volume
Control Post (10)
.
Diagram 3