  All equipment undergoes final inspection and testing before leaving our factory. However, 

if equipment is damaged during shipping or through any other circumstances, it must not 

be used in service. Please check the device regularly for damages. Damaged parts 

should be replaced immediately. 

  All power/air/water/gas sources should be rated for the demands of the device as listed in 

the technical data sheets. Maximum ratings must not be exceeded. All VDE (Verein 

Deutscher Elektro-Ingenieure) standards should be followed. Equipment should be 

grounded according to standards. 

  Adherence to valid regulations regarding necessary checks (e.g. according to Accident 

Prevention & Insurance or electrical equipment) is exclusively taken over by the 

buyer/user of this product. 

  This device has been designated to be used only for its intended purpose. All other 

applications must be prohibited for safety reasons as otherwise 

the manufacturer’s 

warranty expires. 

  The device should be set-up in a clean, well-ventilated room, if necessary under a hood. 

  Supporting surfaces should be straight, flat and adequately stable. 

 

Don’t place anything on top of the machine. 

  To avoid injury, appropriate protection should be worn (e.g. gloves, safety glasses, safety 

shoes, hearing protection etc.) 

  If the machine is defective or working improperly it must be taken out of service. In case 

of further use of the machine the owner will be held responsible for any consequential 

damage. 

  To prevent accidents from water, fire or explosion, all power/air/water/gas sources should 

be turned off after working hours and during breaks, and secured against unauthorized 

access. 

  When carrying out maintenance works or repairs or when opening the device always turn 

off the main power switch and unplug the whole unit. 

  Repairs should be carried out only by the manufacturer or by qualified and certified 

personnel appointed according to chapter 7 

– warranty. 

  In case of leaking water out of housing or tank shut down device and call service. 

  Check all hose connections for leak tightness, if necessary tighten hose clamps again 

 

 

Содержание STAR

Страница 1: ...Operating Instructions LABORATORY EQUIPMENT STAR REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com ...

Страница 2: ...aving unpacked the device please check carefully whether transportation damages of any kind have occurred If that is the case the carrier or manufacturer must be notified within 3 days The company will not be responsible for any damages found after that These operating instructions must be read and followed by all personnel who use this device To ensure quick access we recommend to keep it at a sa...

Страница 3: ...FETY INSTRUCTIONS 8 GENERAL SAFETY INSTRUCTIONS 8 SPECIFIC SAFETY INSTRUCTIONS 9 INSTALLATION 10 OPERATION 10 CHRONOLOGICAL RUN OF OPERATION 10 DECALCIFY THE DEVICE WHEN USING NON DISTILLED WATER 10 TROUBLESHOOTING 11 MAINTENANCE 12 WARRANTY 13 DISPOSAL REGULATIONS 16 SPARE PARTS LIST 17 EU DIRECTIVE 18 ...

Страница 4: ...ner STAR Special Accessories Order No 20107000 Wall holder Order No 20121000 Hand pump for descaling Order No 90410000 Descaler 1 000 ml Order No 10106000 BIOSTEAM CENTER with suction Order No 20200000 Water softening device DELIMER COMFORT ...

Страница 5: ... Control lamp lack of water 4 Control lamp heating 5 Heating controller 6 Tank cap 7 Steam gun 8 Steam gun hose 9 Deflector plate 10 Safety valve 11 Temperature limiter 12 Device s fuse 13 Steam gun switch 14 Pistol clip or holder 15 Contact screw ...

Страница 6: ...6 Fig Device view 1 2 3 6 7 8 4 5 9 10 Fig rear view Abb side view Fig safety valve 14 11 12 13 15 ...

Страница 7: ...depth 280 330 330 mm Weight 8 kg Pressure 0 4 bar variable Temperature 150 C Volume 3 5 l Control Pressure via temperature Steam level 1 Filling Manual Housing Laminated steel Made in Germany Subject to Modification Fig Posture for detailed cleaning Fig Posture for fast operation and high ergonomics ...

Страница 8: ...he manufacturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat and adequately stable Don t place anything on top of the machine To avoid injury appropriate protection should be worn e g gloves safety glasses safety shoes hearing protection etc If the machine is defective or working improperly it m...

Страница 9: ... one or two weeks Not necessary if distilled water is used we recommend special accessories Water softening device DELIMER COMFORT The device must not be filled under pressure and not be connected to the water supply The steam jet is only to be aimed at objects which need cleaning never at living beings Only clean objects appropriate for this purpose if necessary first clean sample or test on an i...

Страница 10: ...tion but at low temperature The heating is automatically activated and the lamp 4 shines After approx 18 min pressure has built up and the control lamp 4 goes out 3 Adjust steam pressure with controller 5 4 For dry steam please press steam gun switch 13 Pressure builds up only in the upper quadrant of the control area Pressure builds up with a slight delay Decalcify the device when using non disti...

Страница 11: ...tank cap or seal No steam Device might be calcified valve might be blocked switches or valves might be defective call service No steam pressure Control unit 5 is not set to max Steam gun drops Device might be calcified valve might be blocked Decalcify Electric shocks to the user s hand Permanently touch contact screw 15 at the steam gun see chapter 2 2 Specific safety instructions High seal abrasi...

Страница 12: ...2 Decalcify the device when using non distilled water Note Clean and protect your device at regular intervals with the REITEL stainless steel care spray order no 90405000 to remove lime plaster and dust as well as other contaminants from the surface of the equipment and to prevent corrosion The spray creates a lasting water repellent protective film which helps keep the equipment clean ...

Страница 13: ...have to be addressed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Department Phone 49 0 5472 9432 0 Reception Fax No 49 0 5472 9432 40 2 In case of warranty claim application the sales receipt or your purchase invoice showing the date of purchase of the...

Страница 14: ...mages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature beyond control war inadequate line voltage insufficient ventilation no decalcification insufficient care and cleaning or non adherence to operation and maintenance instructions according to the accompanying operation guide Damage due...

Страница 15: ...advised to backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sales law Place of jurisdiction is our business location 13 If any provisions of this warranty are judged to be illegal or unenforceable the continuation in full force and effect of the remaining provisions will not be prejudiced The pr...

Страница 16: ...16 Disposal Regulations According to valid laws our devices are properly disposed of according to B2B Regulations for proper disposal Pls contact your local dealer for additional information ...

Страница 17: ...nel 1 piece E6063600 Heating incl sealing set E6060000 1 piece E6060400 Clip for steam gun incl Holder 1 piece E6060000 O ring seal set for heating 1 set E7209700 Switch for black steam gun 1 piece E6069900 Pump for decalcification manual operation 1 piece E6064800 Switch with green lamp 1 piece E6065000 Key s protective cap 2 pcs 1 set E6048700 Delay fuse 6 3 A 1 piece E7413500 Round yellow signa...

Страница 18: ...18 EU DIRECTIVE ...

Страница 19: ......

Страница 20: ...n compliance to Quality Mangement System ISO 13485 2016 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com 122021 ...

Отзывы: