Intended use  

 

Arm support intended for support and positioning of the arm is raised position for patients fixed at 
side position during surgery. The product is to be used by medical professionals within a medical 
facility. 

 

Safety regulations 

 

Maximum load: 15 kg in even distribution, corresponding to a patient weight of 250 kg, according to 

EN 60601-1 and EN 60601-2.  
 

Before use, ensure correct function! 
 

When loosening the lock lever on the clamp or on the  arm support to adjust the  position,  support 
underneath the arm support, to prevent it from uncontrolled descend into the bottom position! 
 

Service and preventive maintenance shall be performed by authorized personnel. 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

MAX 15 kg (MAX 250 kg   ) 

 

Содержание 10-389

Страница 1: ...ed to safety Follow these instructions carefully Read User Manual before use It is important to fully understand the content of the user manual before attempting to use the equipment 2021 04 15 Document number M10 389EN rev 01 Lateral arm support 10 389 ENGLISH ...

Страница 2: ...aximum load 15 kg in even distribution corresponding to a patient weight of 250 kg according to EN 60601 1 and EN 60601 2 Before use ensure correct function When loosening the lock lever on the clamp or on the arm support to adjust the position support underneath the arm support to prevent it from uncontrolled descend into the bottom position Service and preventive maintenance shall be performed b...

Страница 3: ...3 User instruction Installation Position adjustment C A D B A B 40 C D 360 360 D ...

Страница 4: ...ith pH 6 8 and warm water Ethanol can be used on metal surfaces Wipe dry with soft cloth Do not use strong acidic or alkaline detergent Control Check that there are no loose parts and that there is no damage to any part Check the lock function in the joints of the arm support Check that the cushion is clean and is not damaged Årlig service Once a year the arm support shall be carefully cleaned mov...

Страница 5: ...1 Nut left threaded 1 10302 12 Adjustment nut 1 10301 13 Set screw MSK6SS M5x8 A2 1 14 Screw 1 10303 15 Set screw MSK6SS M4x5 A2 1 16 Lever 1 10304 17 Ball 1 K20M6S 18 Lock lever 1 10062 Technical specification Maximum work load 15 kg in even distribution corresponding to a patient weight of 250 kg according to EN 60601 1 and EN 60601 2 Weight 2 8 kg Dimension H x W x L 625 x 155 x 450 mm Material...

Страница 6: ...6 Reison Medical AB Eriksbergsvägen 32A 734 92 Hallstahammar SWEDEN 46 0 220 433 99 I order reison se I info reison se ...