Reison 10-308 Скачать руководство пользователя страница 4

  


 

Maintenance 

 

Service, preventive maintenance, adjustment and repair shall be performed by authorized personnel 

only. Altering the construction without a written consent from the manufacturer, is strictly forbidden. 

 

Cleaning 

 

Clean with antiseptic detergent with pH 6 

 8 and warm water. Ethanol can be used. Wipe dry with 

soft cloth. Do not use strong acidic or alkaline detergent.  

 

Control 

 

Check that there are no loose parts and that there is no damage to any part. Check the clamp lock 
function and the function for positioning and locking the accessory pole in the clamp.  

 

Annual service 

 

Once a year the clamp shall be carefully cleaned, moving parts shall be lubricated, the locking function 
shall be tested 

 

 

Содержание 10-308

Страница 1: ...niversal clamp with V stud Ø 1 25 4 mm 10 308 48 Universal clamp with V stud fine serrated gear rotation Ø 16 20 mm Warning This symbol indicates important information related to safety Follow these instructions carefully Read User Manual before use It is important to fully understand the content of the user manual before attempting to use the equipment 2021 03 31 Document number M10 308EN rev 01 ...

Страница 2: ...fessionals within a medical facility Safety regulation Maximum load 25 kg according to EN 60601 1 and EN 60601 2 Before use ensure correct function When loosening the lock levers to adjust the height or clamp position support the accessory to prevent it from uncontrolled descend into the bottom position Service and preventive maintenance shall be performed by authorized personnel MAX 25 kg ...

Страница 3: ...3 User instruction Installation Usage A B A B ...

Страница 4: ...gent with pH 6 8 and warm water Ethanol can be used Wipe dry with soft cloth Do not use strong acidic or alkaline detergent Control Check that there are no loose parts and that there is no damage to any part Check the clamp lock function and the function for positioning and locking the accessory pole in the clamp Annual service Once a year the clamp shall be carefully cleaned moving parts shall be...

Страница 5: ...o 1 Gear ring 1 10542 10542 10542 11839 10542 1 2 Guide 1 10320 10320 10320 11840 10320 3 Stud 1 10325 10429 10325 11842 10325 4 Lock handle 1 10346 10346 10346 10346 10346 5 Gear cylinder 1 10316 10316 11193 11841 10316 1 6 Lock handle 1 10062 10062 10062 10062 10062 7 Screw MKFT M4x8 A2 1 8 Set screw MT6SS M5x6 A2 2 9 Washer PB 5x10x5 1 ...

Страница 6: ...ht 1 0 kg Material clamp Stainless steel Brass Version UDI DI Dimension H x W x L 10 308 07350111830205 160 x 55 x 120 mm 10 308 P 07350111830243 160 x 55 x 120 mm 10 308 16 07350111830212 160 x 55 x 120 mm 10 308 25 4 07350111830229 160 x 60 x 120 mm 10 308 48 07350111830236 160 x 55 x 120 mm ...

Страница 7: ...7 Reison Medical AB Eriksbergsvägen 32A 734 92 Hallstahammar SWEDEN 46 0 220 433 99 I order reison se I info reison se ...

Отзывы: