background image

6

I. General Information

Important notes on the operation of VEO VOX!
Please read them carefully prior to the operation of the reading system!

 Information on electromagnetic compatibility (EMC)

This opto-electronic reading system with speech output is suited for use in all set-

ups including the domicile that are connected directly to a public power supply for 

buildings with residential purposes.
This system is designed for the use in the indicated electro-magnetic environment. 

The user should ensure the use in the indicated environment.
This system operates on HF-Energy exclusively for its own function. Therefore, the 

emitted interference of high frequency disturbances is very low and the interference 

with other appliances operated close-by is improbable. When operating the reading 

system simultaneously with other systems, however, the possibility of disturbances 

of the system or other systems should not be neglected.
For this reason, it should be ensured that the system is not placed directly beside 

or on top of another system. If the set-up of this system in the proximity of medical, 

measuring devices cannot be avoided, the operator of these devices must be
informed that it is necessary to observe the performance of the system to control the 

conventional use of the system in the chosen set-up.
Electronic devices are sensitive towards electric discharge and towards high  

frequency electromagnetic fields.

Caution: 

To avoid high frequency disturbances (e.g. microwaves), the operator should main-

tain a minimum distance of one meter / three feet away from portable and mobile 

HF-telecommunication devices.
Please also see chapter: Safety advice (page 7).

Storage of the user manual

The user manual is an essential part of your reading system. Please keep the book- 

let in a safe place for future reference.

Product description

VEO VOX is an opto-electronic reading system with an integrated camera to magnify 

text and pictures and to convert print into speech. It corresponds to product category 

25.21.85 of the register of approved aids and complies with all quality and functional 

requirements herein: 

 

 High quality text-to-speech function in natural voices. Reading speed and volume 

can be adjusted individually.

 

 Clear and precise voice output in two applications: 

Continuous reading mode

 

with automatic movement recognition, enables continuous reading without inter-

ruption, and 

Still Capture reading mode

 which enables reading of a scanned 

text in different visualisation modes.

 

 Capture and display of unlimited print (newspaper, book, DIN A4, 8.5” x 11”) with-

Содержание VEO VOX VEOVOT24

Страница 1: ...VEO VOX EN User manual Please read this user manual carefully prior to installation use and maintenance for your own safety and in order to avoid damages on your system...

Страница 2: ...2...

Страница 3: ...5 EU Council directive 93 42 EEC of 14th June 1993 concerning medical devices risk class I according to Annex IX standard 12 CE conformity of Annex VII and RoHS II Council directive 2011 65 EEC Die CE...

Страница 4: ...8 Special care needed when transporting and storing 8 Disposal of the unit according to EU directive 2002 96 EEC 8 Power supply 8 Safety instructions 9 II Instructions for reading system VEOVOX 10 Del...

Страница 5: ...Choosing Reading Area Cross Hair symbol 18 Continuous Reading mode 18 Still Capture Mode 21 VOX Menu adjustments 23 VOX options Reading 24 Description of 3 button remote control bottom up view 26 Bot...

Страница 6: ...that it is necessary to observe the performance of the system to control the conventional use of the system in the chosen set up Electronic devices are sensitive towards electric discharge and toward...

Страница 7: ...of safety operation of a product We fulfill hereby legal requirements and determine for formal reasons a period of three years after date of first purchase Note The mentioned life span does not refle...

Страница 8: ...damp cloth and a mild household detergent Interior of device must NOT come in contact with liquids Special care needed when transporting and storing For safety reasons the unit must only be transport...

Страница 9: ...harm the picture quality 6 Do not operate this device below 5 C or above 40 C 7 Keep liquids away from the system Only operate the device in a dry environ ment 8 The device should not be operated nex...

Страница 10: ...arefully by lifting at the chassis arm while placing support under the XY table Be sure to place unit on a stable surface with sufficient space This may require more than 1 person In case more space i...

Страница 11: ...l The remote control operates on 2 x AA batteries 1 5V Detach the cover on the flipside of the remote control Put in the batteries and make sure that polarity is correctly matched Replace the cover on...

Страница 12: ...e moni tors height and angle according to the most ergonomic position see below The monitor can be moved vertically up The monitor can be rotated anti and down clockwise by 90 degrees to make column r...

Страница 13: ...on can be continuously adjusted from minimum to maximum The yellow friction brake is used for the x axis and the black brake for the y axis x and y axis can be moved into all directions x axis is lock...

Страница 14: ...ng system has been connected correctly to a power supply turn the unit ON by pressing the large center Zoom button on the remote control A short flash of the lighting will appear After a few seconds t...

Страница 15: ...By having the autofocus activated the camera adjusts the picture sharpness automatically The autofocus function can be individually adjusted in the internal VEO menu See page 28 Left button Color sele...

Страница 16: ...be limited to desired text positions cross hair or pre selected columns column mode see control panel Cross hair All print even bigger than DIN A4 8 5 x 11 e g books newspapers etc can be read aloud c...

Страница 17: ...ed it means it is in viewing mode If the icon is green then reading mode is active Decision between Continuous Reading and Still Capture mode By tapping the M icon Mode the system switches between the...

Страница 18: ...mplete text that is visible on the screen will be scanned and read aloud Column Only the column will be read aloud that is marked by two arrowheads Note This icon is replaced by the skip mode symbol a...

Страница 19: ...ment and read it line by line PAUSE Pauses reading the document During reading the PAUSE icon will replace the PLAY icon Reading will be paused to choose a different text area within the scanned docum...

Страница 20: ...ccording to your needs Delete image from image gallery Select an image and tap and hold it for approx 2 seconds until an X appears If you do not want to delete this image tap and hold this image again...

Страница 21: ...Additional virtual modes can be selected Image Overlay Column Horizontal Vertical Word Within the internal menu Settings Display Visualisations list you can activate deactivate custom options accordin...

Страница 22: ...be paused to choose a different text area within the scanned document that shall be read If you don t want to choose a different text area just press PLAY Reading will continue from the position where...

Страница 23: ...e deleted Export Import images Functions will be available with further update Tool Call Exit VEOVOX internal menu Briefly tap this icon to open the internal menu for further individual adjustments Vo...

Страница 24: ...front styles Enabled Disabled Retain font sizes in layouts Enabled Disabled Line spacing adjustment range from 1 to 5 Character spacing adjustment range from 1 to 5 Visualisations list Highlight word...

Страница 25: ...rench Norwegian choose between 30 languages Voice different voices depending on language Text size adjustment range from 1 to 40 Scrollbar size adjustment range from 1 to 10 Cursor size adjustment ran...

Страница 26: ...turning OFF the VEO the last selected level of lighting will be saved 1 2 Settings System Installed Version Installed software Version Camera firmware version Installed Camera Firmware Version Reinec...

Страница 27: ...the black control button 1 at the bottom of the control unit for approx 3 sec onds until the main menu appears on the screen Change options with 3 button remote control Move up down in the menu Turnin...

Страница 28: ...ottom Shadowing covers up to max 80 Left Right FS Shadowing left right Shadowing covers up to max 80 Top Bottom FS Shadowing top bottom Shadow ing covers up to max 80 Full Screen Shadowing covers whol...

Страница 29: ...Colors User color 1 Red Adjustment range from 0 to 31 User color 1 Green Adjustment range from 0 to 31 User color 1 Blue Adjustment range from 0 to 31 User color 2 Red Adjustment range from 0 to 31 Us...

Страница 30: ...Messages OSD Messages ON OFF Main menu Advanced Settings Special Settings Max Digital Zoom Deactivated adjustment range from 1 5x to 15 0x Store User Settings Press Button Zoom or touchscreen to store...

Страница 31: ...at Recognition is enabled My invoice is read out column by column but it should be read out line by line Make sure that the Single column recognition item at the VOX menu at Recognition is enabled My...

Страница 32: ...full screen full page column or from a certain word via crosshair automatic language recognition by sentence more than 30 languages with over 100 voices included Navigation paragraph sentence word let...

Страница 33: ...Repairs not authorized by or from persons other than Reinecker Vision GmbH authorized specialists may lead to invalidity of warranty 5 Partial warranty is valid for light sources serving to illuminat...

Страница 34: ...Notes...

Страница 35: ...Type VEOVOX VEOVOT24 Serial number Manufacturer Reinecker Vision GmbH Final examination Power supply 100 VAC 240 VAC 50 60 Hz Via plug in power suppy 12V DC 8000mA Power consumption max 80 watt...

Страница 36: ...m Servicefall direkt an unser Hauptwerk in Alsbach H hnlein oder an eine unserer Niederlassungen Bei im Ausland erworbenen Produkten kontaktieren Sie im Servicefall bitte Ihren dort ans ssigen H ndler...

Отзывы: