1.

 

About This Manual 

1.1.

 

Disclaimer - This manual was written to provide proper guidelines for using 
the TM-GL Mobile Trans-Former.  Using the TM-GL Mobile Trans-Former in a 
manner other than detailed in this manual can be dangerous and can cause 
serious property damage and injury.  The user accepts all risks and Reina 
Imaging shall not be responsible for any liability caused by improper use.  
Reina Imaging 

assumes no responsibility to assess the user’s technical ability 

or clearance to operate the TM-GL Mobile Trans-Former.  Use of the TM-GL 
Mobile Trans-Former 

constitutes the user’s acceptance of all responsibility 

for liability caused by its use. 

1.2.

 

Additional Information Concerning Risks - Throughout this manual additional 
information is presented to the user to aid in understanding of risks during 
certain operations.  This additional information is not comprehensive of all 
risks assumed by the user and this product should only be operated by 
trained persons possessing the technical expertise required for safe 
operation. 

There are three types of additional risk-related information presented to the 
user: 

 

Caution

 

 Cautions in this manual contain information to help the user 

avoid minor risks such as product problems due to improper assembly or 
usage.  Failure to heed this level of warning may result in product failure, 
minor product damage, unusable product, property damage and the like.   

 

The user or patient may also experience minor injuries. 

 

 

 

The Caution Symbol 

 

 

Warning

 

 Warnings in this manual contain information to help the user 

understand substantial risks.  Failure to heed this level of warning could 
result in serious product damage and serious property damage.   
 
The user or patient may also experience serious injuries that would likely 
require medical attention. 

 

 

 

The Warning Symbol 

 
 
 

Содержание TM-GL

Страница 1: ...on Guide MAN 0009 A EFFECTIVE 12 09 19 Reina Imaging 6107 W Lou Ave Crystal Lake IL 60014 800 752 4918 www reinaimaging com TM GL Mobile Trans Former Installation Guide and User Instructions Model TM...

Страница 2: ...1 Uncrating 6 3 2 Assembly 6 4 Uncrating the Device 7 4 1 Uncrating Two People to Remove from Pallet 7 4 2 Removing Cardboard Container 7 5 Installing the D EVO GL Panel Grid and DR Panels 8 5 1 Safe...

Страница 3: ...the unit and these instructions Do not attempt to adjust the Detector Mount height prior to reading the instructions Failure to adhere to the Precautions listed herein may result in injury to user or...

Страница 4: ...mpair the use of the product The company will repair or replace at its option without charge to the original purchaser only the defective products or parts for a period of 1 year from the date of purc...

Страница 5: ...nal information is presented to the user to aid in understanding of risks during certain operations This additional information is not comprehensive of all risks assumed by the user and this product s...

Страница 6: ...ll our support line for the latest materials regarding this system prior to use Users should check back periodically for updates and checking before installation of the product s is recommended 2 Prod...

Страница 7: ...and box and remove the box top Remove the remainder of the box from the pallet Remove all bracing and strapping Removing Cardboard Container Figure 4 2 Installation Precautions The unit is pre assemb...

Страница 8: ...r when rotated See Section 6 for full explanation of controls before performing these operations NOTE Some images in this manual do not reflect the D EVO GL Long Length DR Panel product however the wo...

Страница 9: ...5 2 5 3 Installing the D EVO GL Panel Make sure the tensioner knobs are fully loosened by turning them clockwise until they stop see Figure 5 6 for reference Install the D EVO GL Panel into the Detec...

Страница 10: ...r Grid The TM GL is a mechanical device that requires a constant load in the Detector Mount to maintain a zero gravity feel for the user The mock up grid must be installed into the Detector Mount behi...

Страница 11: ...M GL Lower the Detector Mount to its lowermost position Hold the frame from the rear near the top place foot on bottom of frame and tilt the device back toward you It will then be riding on the wheels...

Страница 12: ...e that relies upon coil springs and pulleys to control the height adjustment movements The unit will move very easily near the center of its stroke Extra effort is required to reach the uppermost and...

Страница 13: ...the release pin in the right side handle and raise or lower the Detector Mount Adjusting Height of D EVO GL Panel Figure 6 2 6 3 D EVO GL Panel Rotation To turn the D EVO GL Panel from portrait to lan...

Страница 14: ...eate motion induced blurring in the resultant image 6 4 Patient Position The patient should stand on the tongue of the TM GL to stabilize the device Standing on the Tongue PA AP Figure 6 4 7 Maintenan...

Страница 15: ...Ave Crystal Lake IL 60014 800 752 4918 www reinaimaging com Page 15 of 15 ALL QUESTIONS AND CONCERNS SHOULD BE FORWARDED TO REINA IMAGING 6107 W LOU AVE CRYSTAL LAKE IL 60014 800 752 4918 www reinaim...

Отзывы: