Compressor is not running (connected to AC supply)
Poor cooling, increase in interior temperature
Unusual noises
Problem
Possible cause
Remedy
No voltage
Connection supply line inter-
rupted
Establish a connection
Main switch faulty (if
installed)
Replace the main switch
Additional supply line fuse
has blown (if installed)
Replace the supply line fuse
Voltage is present but the
compressor doesn't run
Ambient temperature too
high
-
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between the
pins in the compressor inter-
rupted
Defective compressor
Contact customer service
Problem
Possible cause
Remedy
Compressor runs for a long
time/continuously
Ambient temperature too high -
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty Fan
Replace the fan
Compressor does not run
often
Battery capacity exhausted
Charge the battery
Problem
Possible cause
Remedy
Loud humming
A component of the refriger-
ant circuit cannot move freely
(touching the wall)
Bend the component care-
fully away from the obstruc-
tion
There is a foreign object
stuck between the cooling
unit and the wall
Remove the foreign object
Fan Noise
Replace the fan