Power Supply 

Voltage:

C = 208V

E = 240V

G = 380V

J = 415V

K = 480V

M = 600V

HLR120 ‐ HLR180 HOW WATER BOILERS

4407 Martinsburg Pike

Phone: 540­662­3811

Clear Brook, VA 22624

Fax: 540­665­8101

USA

                     

email: [email protected]

web: www.reimersinc.com

Maximum design 100psi, 250°F

Maximum opera ng 85psi, 235°F

All boilers are manufactured in accordance with the
requirements of the A.S.M.E. Boiler and Pressure Vessel
Code and A.S.M.E. CSD‐1. Each boiler bears the Na onal
Board Stamp “H”.

Shell fiberglass insula on thickness minimum 2".

Power range 120kW ‐ 180kW with up to 6 hea ng stages, depending 

on model.

Hea ng stages managed by digital step controller.

Features

Standard Equipment of Each Boiler Includes:

A.S.M.E. pressure relief valve

One (1) primary high temperature cutoff control with automa c reset 
and  one  (1)  secondary  high  temperature  cutoff  controll  with  manual 
reset

One (1) low water cutoff control w ith manual reset

PID‐step  controller  with  number  of  hea ng  stages  depending  on  the 
boiler hea ng power

Digital readout of the opera ng temperature

Magne c contactors

Internal branch circuit fusing

Main supply power distribu on block

Indicator  lights  for  POWER,  HEATING,  CIRCULATOR  PUMP,  and 
ALARMS

Pressure and temperature gauges

Applications

•  Space Hea ng
•  Tank Hea ng

•  Water Source Heat Pumps
•  Swimming Pools

Model Number Key

Boiler Power in kW

Safety Relief

Valve Setting:

A = 15psi (1.0 bar)

B = 30psi (2.1 bars)

C = 50psi (3.4 bars)

D = 60psi (4.1 bars)

E = 75 psi (5.2 bars)

F = 100psi (6.9bars)

Power Supply:

1 = 1­Phase

3 = 3­Phase

Example: HLR180K3B = HLR‐Series hot water boiler, 180kW 
hea ng power, power supply 480V, 3ph, safety valve set to 
30psi

* Each boiler model requires two (2) power supplies: 
Hea ng power and control voltage. Nominal control 
voltage is 120V AC. Boiler models rated for 380V and 
415V 

are 

equipped 

with 

control 

voltage 

transformers that require 220/240V applied to their 
primary side in order to provide the 120V AC control 
voltage to the boiler. As an op on, all boiler models 
can  be  equipped  with  control  voltage  transformers 

so  that  only  the  hea ng  power  supply  needs  to  be 
connected to the boiler.

Please note that all information provided within this brochure is approximate and subject to change without notice.

Please contact Reimers Electra Steam, Inc. with any questions regarding the specifications or dimensions detailed within.

•  Bio‐Diesel Reactors
•  De‐Icing

H L R

Содержание HLR120

Страница 1: ...120 180 Manual English REV 1 4407 Martinsburg Pike Phone 540 662 3811 Clear Brook VA 22624 Fax 540 665 8101 USA email sales reimersinc com web www reimersinc com _______ MODEL ________ SERIAL HLR 120...

Страница 2: ...Boiler Startup 9 Honeywell Controller T775P2003 Setup 9 Honeywell Controller T775P2003 Setting Operating Parameters 9 Boiler Startup 9 Boiler Maintenance 10 Tightening the Electrical Terminal Connect...

Страница 3: ...c contactors Internal branch circuit fusing Main supply power distribu on block Indicator lights for POWER HEATING CIRCULATOR PUMP and ALARMS Pressure and temperature gauges Applications Space Hea ng...

Страница 4: ...t are normally expendable in usual course of operation Claims against carriers for damage in transit must be filed by the buyer Reimers liability if any will not exceed the price of Reimers products c...

Страница 5: ...es Located on electrical enclosure door Located on end caps of cylindrical boiler pressure vessel jacket Located on end caps of cylindrical boiler pressure vessel jacket This manual contains safety me...

Страница 6: ...he internal pressure of the boiler It can fail Periodically have your boiler inspector compare the gauge with a known gauge utilizing the test valve arrangement provided 6 REGISTRATION Most states and...

Страница 7: ...he working space or exposed live parts on both sides of the working space that are effectively guarded by insulating materials Condition 2 Exposed live parts on one side of the working space and groun...

Страница 8: ...recognized water treatment company located in your area Recommended levels for boiler feed water Recommended levels for boiler water water inside pressure vessel when boiler is operating The safety va...

Страница 9: ...D LAG FOFO 1 3 3 9 DI OPTIONS DISABLE 1 3 3 10 SHOW RT NO EXIT 1 3 4 Setting up the Stages Not set EXIT 1 4 Setup Alarms Not set EXIT PROGRAMMING OUTPUT STAGES WITH NO RESET 3 1 Entering Program Mode...

Страница 10: ...E alarm light will turn on and all heating stages turn off immediately Frequency During boiler installation 90days after boiler installation and then annual Re tighten the terminals of the contactors...

Страница 11: ...ch in the middle OFF position Observe the LOW WATER alarm light in the boiler controller front panel If it turns ON the low water cut off device works properly Close the boiler drain valve open the in...

Страница 12: ...s the LOW WATER RESET switch The LOW WATER alarm light should turn OFF The hot water boiler should be ready for operation 4 Troubleshooting WARNING Ensure that the boiler is cold and has no pressure E...

Страница 13: ...s list for HLR 120 180 WARNING Use Reimers replacement parts All components are designed and approved to be used in this Underwriters Laboratories listed and ASME National Board Stamped boiler Failure...

Страница 14: ...PAGE 14 Reimers Electra Steam Inc 01 10 2022 HLR 120 180 Manual English REV 1 NOTE When ordering parts please give boiler Model and Serial Number and detail shipping instructions...

Отзывы: