Reimers Electra Steam, Inc. 01/10/2022
HLR 120‐180 Manual ‐ English
REV 1
Power Supply
Voltage:
C = 208V
E = 240V
G = 380V
J = 415V
K = 480V
M = 600V
HLR120 ‐ HLR180 HOW WATER BOILERS
4407 Martinsburg Pike
Phone: 5406623811
Clear Brook, VA 22624
Fax: 5406658101
USA
email: [email protected]
web: www.reimersinc.com
•
Maximum design 100psi, 250°F
•
Maximum opera ng 85psi, 235°F
•
All boilers are manufactured in accordance with the
requirements of the A.S.M.E. Boiler and Pressure Vessel
Code and A.S.M.E. CSD‐1. Each boiler bears the Na onal
Board Stamp “H”.
•
Shell fiberglass insula on thickness minimum 2".
•
Power range 120kW ‐ 180kW with up to 6 hea ng stages, depending
on model.
•
Hea ng stages managed by digital step controller.
Features
Standard Equipment of Each Boiler Includes:
•
A.S.M.E. pressure relief valve
•
One (1) primary high temperature cutoff control with automa c reset
and one (1) secondary high temperature cutoff controll with manual
reset
•
One (1) low water cutoff control w ith manual reset
•
PID‐step controller with number of hea ng stages depending on the
boiler hea ng power
•
Digital readout of the opera ng temperature
•
Magne c contactors
•
Internal branch circuit fusing
•
Main supply power distribu on block
•
Indicator lights for POWER, HEATING, CIRCULATOR PUMP, and
ALARMS
•
Pressure and temperature gauges
Applications
• Space Hea ng
• Tank Hea ng
• Water Source Heat Pumps
• Swimming Pools
Model Number Key
Boiler Power in kW
Safety Relief
Valve Setting:
A = 15psi (1.0 bar)
B = 30psi (2.1 bars)
C = 50psi (3.4 bars)
D = 60psi (4.1 bars)
E = 75 psi (5.2 bars)
F = 100psi (6.9bars)
Power Supply:
1 = 1Phase
3 = 3Phase
Example: HLR180K3B = HLR‐Series hot water boiler, 180kW
hea ng power, power supply 480V, 3ph, safety valve set to
30psi
* Each boiler model requires two (2) power supplies:
Hea ng power and control voltage. Nominal control
voltage is 120V AC. Boiler models rated for 380V and
415V
are
equipped
with
control
voltage
transformers that require 220/240V applied to their
primary side in order to provide the 120V AC control
voltage to the boiler. As an op on, all boiler models
can be equipped with control voltage transformers
so that only the hea ng power supply needs to be
connected to the boiler.