REID LIFTING PORTADAVIT QUANTUM Скачать руководство пользователя страница 1

US.

REID

LIFTING.COM

Assembly & Operation Guide

PORTA

DAVIT

  QUANTUM

Содержание PORTADAVIT QUANTUM

Страница 1: ...US REIDLIFTING COM Assembly Operation Guide PORTADAVIT QUANTUM...

Страница 2: ...ons Maintenance Repair Storage Transportation Overload Indicator Sockets Socket Installation Minimum Mounting Requirements Verifying the Installation ATEX 12 ATEX Classification Zone 2 Classification...

Страница 3: ...They apply for Operation including preparation troubleshooting during operation and cleaning Maintenance inspection and repair Transportation It is the responsibility of the end user to adhere to the...

Страница 4: ...eased safety factor The maximum capacity permitted by the personnel winch accessory used in conjunction with the product also needs to be taken into account If this product is to be used for lifting o...

Страница 5: ...it is attached in a way that does not expose the user to danger by the hoist chain or load Do not allow the load to swing To avoid side pull lowering and lifting should only be carried out when the l...

Страница 6: ...such as trapping fingers in rotating parts Be aware of any adverse weather conditions such as strong or gusty winds which could impose additional horizontal loads and affect the stability of the stru...

Страница 7: ...abrasion climatic exposure on the fall protection lifelines and the effect of offset forces as a result of pendulum falls Where regulations require each installation must be approved by a qualified pe...

Страница 8: ...the free rotation of the kingpin and ensure that it is fully engaged in the socket The lower bearing at the bottom of the column needs to be flush with the top of the socket Regular Inspections To ens...

Страница 9: ...cturer only Failure to do so could have an impact on the structural performance and stability of the product Storage Transportation When transporting the components take note of all the manual handlin...

Страница 10: ...on Socket installation should only be carried out by a qualified person with the ability to specify the anchors resin and fasteners necessary to ensure an installation that is safe for use If in any d...

Страница 11: ...rs When verifying the installation testing should be to no more than 125 of the goods capacity at its maximum reach All tests should be carried out in all anticipated worst case loading directions sus...

Страница 12: ...are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only The product will have the following identification on the serial label As Standard for Zone...

Страница 13: ...n earthing cable should be used Inspection Maintenance Repair Special attention should be given to dust deposits on the structure especially in areas where the profiles come into contact and should be...

Страница 14: ...Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Strop Column Restraint Poin...

Страница 15: ...ckle position and the lower value stating the inner shackle position The operating dimensions can be found on page 19 15 PORTADAVIT QUANTUM Assembling the PORTA DAVIT QUANTUM Type S Shackle only Holes...

Страница 16: ...lication Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Column Restraint Point Kingpin Sheave Bracket Assembly Head Lower Jib Carry Handle Harken LokHead Doub...

Страница 17: ...s the ground ensuring that the backstay remains inside the column fins 17 PORTADAVIT QUANTUM Caution Potential finger trap Assembling the PORTA DAVIT QUANTUM Type W Winched Holes on the lower and uppe...

Страница 18: ...rting the pin in the adjustment plate The decal specifies the reach values with the upper value stating the outer shackle position and the lower value stating the inner shackle position Assembly Instr...

Страница 19: ...19 PORTADAVIT QUANTUM Notes PORTADAVIT QUANTUM Variants Options 19...

Страница 20: ...in the head of the davit to support the rotation The rotation should be done in a controlled manner When the rotational handle is attached to the Davit the following points must be observed Attach the...

Страница 21: ...21 PORTADAVIT QUANTUM Notes...

Страница 22: ...QUANTUM Shackled Dimensions Overall height Height to outer shackle Height to inner shackle Radius to outer shackle Radius to inner shackle A B C D E A B C E D C E D B A C B A E D A E B C D 66 14 116...

Страница 23: ...Part Number Capacity lbs A B C D E US PDQ1S 1320lbs 1 79 76 70 47 43 2 81 78 72 43 39 US PDQ1W 3 83 80 74 39 35 US PDQ2S 1100lbs 1 72 69 64 59 55 2 74 72 67 55 51 US PDQ2W 3 77 74 69 51 47 Dimensions...

Страница 24: ...nt environmental issues and the health and safety practices within the company ISO 9001 2015 Quality management system which assesses an organization s ability to consistently provide products that me...

Страница 25: ...been carried out by SGS Fimko Oy Takomotie 8 FI 00380 Helsinki Finland CE body no 0598 in accordance with Module D PPE Regulation EU 2016 425 Testing Testing and technical file review are integral par...

Страница 26: ...he following labels must be present on the product and must be legible lbs 1 2 3 4 5 6 7 Dependent on the product purchased Winched varients will be labelled with label 1 on the backstay 1 2 3 4 5 6 7...

Страница 27: ...umber The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Minimum braking load MBL Period...

Страница 28: ...m Printed using environmentally friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names are Trade Mark and Trade Name protected...

Отзывы: