BOOSTER.PRO welding systems are designed in accordance with EN 60974-1 
Arc welding equipment - welding power sources for overvoltage category III and 
pollution degree 3 and in accordance with EN 60974-10 Arc welding equipment 
- electromagnetic compatibility (EMC) for Group 2 Class A and should be suita-
ble for use in all areas, except residential areas that are connected directly to a 
public low-voltage supply system. It may possibly be difficult to ensure  
electromagnetic compatibility in these areas due to both conducted and radiated 
interference. For this purpose, the use of appropriate measures to meet the  
requirements (filters for mains connection, shields such as shielded cables, the 
shortest possible welding cables, earthing of the workpiece, potential  
equalization) and assessment of the environment (such as computers,  
controllers, radio and television broadcasters, adjacent people, for example  
required in the use of cardiac pacemakers) are required. The responsibility for 
any fault lies with the user. For more information and recommendations, see,  
inter alia, DIN EN60974-10: 2008-09, Annex A. 
 

Qualification of the operating personnel 

REHM  welding  systems  should  be  operated  only  by  persons  who  are  trained 
and instructed in the use and maintenance of welding systems. Only qualified, 
assigned and trained personnel may work on and with the system. 
 

Personal protective equipment (PPE) 

Personal  protective  equipment  (PPE)  is  required  when  working  with  a  welding 
system: 

 
• Welding protection filter, protection level 10-15 
• Protective shield, screen or hood 
• Protective gloves 
• Leather apron 
The employer is obligated to provide the required PPE to the operator 
 

Environmental conditions 

• Temperature range of ambient air: 
  

-  In operation: 

 

 

-10°C to +40°C (10°F to 104°F) 

  

-  During transport and storage:   -20°C to +55°C (-4°F to 131°F) 

• Relative humidity: 
  

-  to 50% at 40°C (104 °F) 

 

-  to 90% at 20°C (68 °F) 

• Ambient air: 
   Free of unusual amounts of dust, acids, corrosive gases or substances, etc.,  
   unless they are produced during welding. 
• Altitude above sea level: Up to 2000m (6500 ft). 
 
Operation and storage of the system outside the specified range is considered 
to be improper. The manufacturer is not liable for any resulting damage. 
 

Requirements on the mains supply 

The system may be connected and operated from a single phase 2-wire system 
with earthed neutral conductor. 

 

 

Содержание 1513230

Страница 1: ...GB REHM SCHWEISSTECHNIK BOOSTER PRO 230 Electrode inverter SHORT GUIDE...

Страница 2: ...te of issue 17 08 2020 REHM GmbH u Co KG Uhingen Germany 2020 The content of this description is the property of Rehm GmbH u Co KG The copying and distribution of this document its use and communicati...

Страница 3: ...iption 5 3 Operation description 6 3 1 Overview oft he operating panel 6 3 2 Operation in the main menu Menu 1 7 3 3 Current curve Menu 2 8 3 4 Settings Menu 3 10 4 Circuit diagram 11 5 Maintenance wo...

Страница 4: ...n dangerous hazards and the intended use of the system is no longer guaranteed The dismantling of safety devices for equipping repairing and maintenance is described in detail The safety devices must...

Страница 5: ...alia DIN EN60974 10 2008 09 Annex A Qualification of the operating personnel REHM welding systems should be operated only by persons who are trained and instructed in the use and maintenance of weldin...

Страница 6: ...f controls 6 Drawer storage for electrodes gas nozzles etc 2 Control panel push and rotate knob 7 Main switch On Off 3 Current socket negative TIG TIG welding torch Electrode Workpiece or electrode ho...

Страница 7: ...reen Operation via rotary encoder with push button Fig 2 Push and rotary encoder Rotary encoder with push knob Moves the pointer cursor on the screen clockwise or counter clockwise Positions reached a...

Страница 8: ...l has to be set Display of the welding function Procedure Boost Explanation Rutile electrode No with fuse hold Basic electrode No with fuse hold Rutile electrode Yes Basic electrode Yes WIG LiftArc Th...

Страница 9: ...ctive Pulse current I1 is the current displayed on the main screen Menu1 which can also be adjusted from there When time pulses occur current I1 is only present for time t1 and then changes to current...

Страница 10: ...lse On Off If the symbol is displayed in blue the time pulse is activated in black it is deactivated If the pulse is inactive the I2 display goes out HYPER PULSE On Off If the symbol is displayed in b...

Страница 11: ...rc Software version of the machine Power control Software version of the operation The fuse limitation can be activated or deactivated here Limits the maximum adjustable current Setting Electrode max...

Страница 12: ...11 4 Circuit diagram...

Страница 13: ...result in operating faults Periodic maintenance of the system is therefore essential No constructive change or additions may be made to the system 5 2 Maintenance table The maintenance intervals are r...

Страница 14: ...y requirements for arc welding units in accordance with the following product standards EN 60974 1 2018 12 Arc welding equipment Part 1 Welding current source EN 60974 3 2015 12 Arc welding equipment...

Страница 15: ...14...

Страница 16: ...Stand 08 2020 Artikel Nr 7302157...

Отзывы: