1 Safety information, maintenance and defects

1.1 Use of the device

The  i-Pulz  is  an  external  stimulator  used  for  pain  treatment  among 
people  suffering  from  chronic  and  acute  pain.  Do  not  use  the  nerve 
stimulator for other purposes. Use it only with permission from a medical 
specialist.

1.2 Precautions

• 

Make sure the nerve stimulator does not get hit, falls or is used 
inappropriately to avoid it getting damaged.

• 

Check the nerve stimulator and cables for any inconsistencies 
before using it. Do not use if damaged or degraded in any way.  
Replace immediately.

• 

Do not use the nerve stimulator when driving or controlling heavy 
machinery.

• 

Always  check  if  the  nerve  stimulator  is  switched  off  before 
removing or placing electrodes. 

• 

While it is not necessary to store the nerve stimulator in its carry 
case when not being used or when being transported, it is ad-
visable to do so for safety and added protection from dust, pet 
hairs, pests or insects.

• 

Remove the device from its carry case when intending to use it.

• 

Avoid the use of accessories, detachable parts and materials not 
described in this manual as these may make the device 

• 

unsafe for use or compromise the selected therapy.

• 

Avoid connecting the device to other equipment not described 
in  this  manual  as  this  may  make  the  device  unsafe  for  use  or 
compromise the selected therapy.

• 

Do not wrap electrode cables around the neck as this could lead 
to serious injury or strangulation.

• 

The application of electrodes near the thorax may increase the 
risk of cardiac fibrillation. If in doubt, consult with a specialist.

Содержание i-Pulz

Страница 1: ...i Pulz User Manual i Pulz User Manual...

Страница 2: ......

Страница 3: ...aintenance of the batteries 8 1 9 Battery charger 8 1 10 What to do in case of a defect 9 2 The i Pulz nerve stimulator 9 2 1 General 9 2 2 Controls 9 2 3 Buttons 10 2 3 1 On off 10 2 3 2 Mode 10 2 3...

Страница 4: ...Accessories 23 5 1 Cables 23 5 2 Batteries and charger 23 5 3 Removing adhesive residues 23 5 4 Treating the irritated skin 24 5 5 Disposable electrodes 24 5 6 Reusable electrodes 24 6 Contents of pa...

Страница 5: ...hed off before removing or placing electrodes While it is not necessary to store the nerve stimulator in its carry case when not being used or when being transported it is ad visable to do so for safe...

Страница 6: ...1 This means that the device is protected from touch by fingers or similar ob jects greater than 12 5mm and is effective against condensation 1 6 Warnings Patients with a pacemaker the nerve stimulato...

Страница 7: ...tenance If needed clean the device with a damp cloth Never use aggressive detergents like ether alcohol or abrasives Never submerge the device in water or in any other liquid In case it does get subme...

Страница 8: ...ve the charger from the wall socket before removing the batteries Warning do not place non rechargeable batteries in the char ger this may cause leakage in those batteries which may re lease dangerous...

Страница 9: ...ls work independently from each other and do not influence each other two different forms of stimulation can therefore be used simultaneously You can also use just one channel The i Pulz has 10 standa...

Страница 10: ...0mA it is possible to reduce the current to 0 immediate by pressing this button 2 3 3 Timer Pressing this button enables you to set a timer for the program Press the timer button multiple times to se...

Страница 11: ...chapter 4 2 4 The display A Preset number remaining time B Timer C Check the user manual D Battery indicator E Keypad lock F Intensity display left channel G Intensity display right channel H Graphic...

Страница 12: ...any accidental increase in the current The key icon indicates that the lock is active Press the intensity down button once of the channel in use to cancel the keypad lock F Intensity display left cha...

Страница 13: ...the daily use of the device there are the following steps Cleansing of the skin Placing of the electrodes Setting up the stimulator Treatment period Stopping the daily treatment period Removing the el...

Страница 14: ...am will appear it is an ongoing list you will reach your starting position eventually Check if the timer is set properly By default the timer is set to 30 minutes per program unless your doctor or spe...

Страница 15: ...rview of all available programs can be found in the back of the manual at the technical specifications 3 4 Treatment period Regarding the treatment period you must strictly adhere to the instructions...

Страница 16: ...ite all the precautions it is possible that you experience irritati on of the skin Many skin creams take good care of your skin but are unfortunately not compatible with nerve stimulation therapy Most...

Страница 17: ...n activated when you the device informa tion is visible on the screen such as the serial number Using the right Up Down button it is possible to select different items in the menu Pressing the Mode bu...

Страница 18: ...ed Please contact your distributor for a new set of cables 4 2 3 Buzzer This option allows you to switch the sound on or off that is heard when the i Pulz is switched on 4 2 4 Default timer The interv...

Страница 19: ...S pulse con ventional TENS always flows from the right channel The right hand side Up Down button are used to select the preset Use the right hand side Up Down button to select EXIT in the menu to ret...

Страница 20: ...ents Description 1 Pulsewidth 30 300 S 2 Frequency 1 175 Hz User Program U3 Step Parameter Adjustments Description 1 Pulsewidth 30 300 S left channel 2 Frequency 1 175 Hz 3 Pulsewidth 30 300 S right c...

Страница 21: ...th 30 300 S right channel 8 Frequency 1 175 Hz User Program U6 Step Parameter Adjustments Description 1 Pulsewidth 30 300 S 2 Amount of pulses 2 25 3 Select combi TENS yes no If yes go to step 4 5 4 P...

Страница 22: ...1 Amount of pulses 2 10 2 Select combi TENS yes no If yes go to step 3 4 3 Pulsewidth 30 300 S right channel 4 Frequency 1 175 Hz User Program U10 Step Parameter Adjustments Description 1 Pulsewidth...

Страница 23: ...Cables 2 cables will be supplied with the device Please contact your distributor if the cables need replacing 5 2 Batteries and charger The i Pulz uses 2 rechargeable AAA batteries Use an appropriate...

Страница 24: ...ady to use system these electrodes are easy to place They are meant for single use and to be disposed afterwards 5 6 Reusable electrodes Reusable electrodes are ready to use adhesive electrodes that c...

Страница 25: ...78x59x28mm Weight 91 grams without battery 115 grams including battery Conditions of use Temperature 5 C to 40 C Air humidity 15 to 93 no condensation Atmospheric pressure 700 hPa to 1060 hPa Storage...

Страница 26: ...HAN 100 150 phase 1 3 seconds 2 200 phase 2 3 seconds P5 HAN combina tion 100 2 150 200 left channel P4 110 80 right channel P1 P6 Burst 100 180 8 pulses 2x per sec P7 Pulsewidth modulation 110 60 tot...

Страница 27: ...orm for both immunity and emission Nonetheless certain precautions must be taken The 2 cables of 1 2 meter Rehan part number 200 01 0044 that are supplied with the device ensure the connection between...

Страница 28: ...onment Emissions Test Compliance Electromagnetic Environment guidance RF emissions CISPR11 Group 1 The i Pulz ES 2 uses RF energy only for its internal function Therefore its RF emissions are very low...

Страница 29: ...ative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines Not applicable The device is battery powered Surge IEC 61000...

Страница 30: ...equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P Radiated RF Electromag netic Field IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m d 1 2 P 80 MHz to 800 MHz...

Страница 31: ...ES 2 The i Pulz ES 2 is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the i Pulz ES 2 can help prevent electromagneti...

Страница 32: ...Rehan Electronics Ltd Brunswick Row Aughrim Road Carnew County Wicklow Tel 353 0 53 942 6742 Fax 353 0 53 942 6051 sales rehanelectronics ie www rehanelectronics com...